SJE Rhombus In-Site EZ Serie Manual De Instalación Y Operación página 3

Con sensor c-level
Ocultar thumbs Ver también para In-Site EZ Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

C-Level™ Sensor Positioning
Keep vent above water level.
Stow excess tube using a
cable tie.
Caution: Do not overtighten
and pinch vent tube.
Do not use the hose clamp
to attach the vent tube.
Doing so will cause sensor
to fail.
4 inch (10.2 cm)
minimum set level
0 inch (0 cm) liquid
level measured from
approximately this point
1 inch (2.5 cm)
minimum from bottom
of tank or from sludge
Timed Dose
high water
alarm
timer
override
timer
enable
redundant
off
0
Float Switch Positioning
hose
clamp
cable
tie
hose
clamp
Demand Dose
high water
alarm fl oat
(recommended)
redundant off
fl oat
(recommended)
CAUTION!
If the C-Level ™ sensor or fl oat
switches are not mounted and
connected correctly, the pumps
and alarm will not operate
properly.
3.5"
(9 cm)
ag (duplex
l
only)
high water
alarm
lead
stop
0
high water
alarm fl oat
(recommended)
redundant
off fl oat
(recommended)
English 3
Tabla de contenido
loading

Tabla de contenido