Mosquito Magnet Commander Manual De Operación página 8

Ocultar thumbs Ver también para Commander:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Maintenan ce
Maintenance
If using one of our Gas Saver Modes, be sure to adjust the dates
on the chart below (see chart on page 11 to coordinate the
maintenance schedule with the mode of operation).
• 21 Day Maintenance Cycle - for Optimal Performance
- Refill propane. (Propane lasts approximately 21 days with
24-hour/7-days operation.)
- Replace short-range attractant cartridge.
See Mosquito Magnet
attractant label for instructions.
®
- Empty or replace bug bag.
- Utilize the Quick Clear adapter at every tank change.
• Periodically wipe down the outside of the trap
with a clean, water damp cloth.
• Charge your battery for 24 hours at the beginning of the season.
Note: Bug bags should be replaced when half full. You can find all your acc essory needs
Maintenance Schedule
Possible Cause
at www.mosquitom agnet.com or at your Certified Mosquito Magnet Hardware or Home Improvemen t Store.
Exampl e
Purchase Date
4/1
Register Warranty
4/1
Start Up Date
4/1
SERVICE:
Seasonal Tune-Up
MAINTENANCE:
Propane, Attractant & Bug Bag Change
4/21
Quick Change Cartridge
4/21
Propane, Attractant & Bug Bag Change
5/11
Quick Change Cartridge
5/11
Propane, Attractant & Bug Bag Change
5/31
Quick Change Cartridge
5/31
Propane, Attractant & Bug Bag Change
6/20
Quick Change Cartridge
6/20
Propane, Attractant & Bug Bag Change
7/10
Quick Change Cartridge
7/10
SERVICE - WINTERIZATION
Discard Bug Bag & Attractant
Cover Trap Trumpe t to avoid
nesting insects
Keep in garage or shed
13
Propane Tank Changing Tips
When attaching the regulator knob to a tank after a tank change,
be sure to fully tighten the regulator knob onto the tank. No need
to use tools, but do turn the knob as far as possible by hand.
When this is done, loosen the knob 1/4 turn, then re-tighten to
maximize seal.
The purpose for this is to fully engage the regulator onto the tank. If
the regulator is not fully engaged, the flow of gas may be restricted
to the point where the trap will show a gas empty code. If this
occurs, press the off button, close the tank valve, and remov e the
regulator from the tank. Re-attach the regulator and try again.
Season 1
Seas on 2
Season 3
Season 4
3/15
Easy Quick Clear Valve
Important: Extinguish all smoking materials prior to use of
Easy Quick Clear Valve. Do not stand directly behind the
Quick Clear cartridge during operation.
Use of PROTECTIVE eyewear is recommend ed.
Important: Shut down your trap. Let fan run until it
stops before using Quick Clear Cartridges (about 5
minutes).
Quick Clear is recommende d for regular maintenance to remov e
built-up contam inants.
Recomm ended for use at every tank change. Also recomm ended for
use before seasonal storage to avoid build up of contaminan ts during the
off-season. Instructions for "Easy Quick Clear Valve" maintenance
procedure shall be provided on a label attached to trap where easily
visible by user.
The Easy Quick Clear Valve is a threaded knob located on the back of
your trap. It should be used with the adapter included with your trap,
and a threaded Quick Clear cartridge available on our website at:
www.mosquitom agnet. c omor at your local hardware or home
improvement store.
1. Important: Shut down your trap. Let fan run until it
stops before using Quick Clear Cartridges (about 5 minutes).
2. Close the propane tank valve by turning to the "OFF" position. (Turn
the tank valve clockwise.)
3. Remove the protective cap from Easy Quick Clear valve located
in the back of the trap.
4. Hand-screw the Quick Clear adapter on to Quick Clear valve, until
finger tight.
5. Hand-screw the Quick Clear cartridge into the Quick Clear
adapter clockwise until hand tight while holding the adapter in
place. Important: Do not over-tighten.
6. While holding the adapter in place slowly unscrew
Quick Clear cartridge up to 1/4 turn only in counter clockwise
direction from the Quick Clear adapter only. The strong flow of
compressed air lasts approximately 45 seconds. Be sure to allow
Quick Clear cartridge to run out completely. (Hissing will stop when
cylinder is empty. Quick Clear cartridge will be cold to the touch.)
7. Unscrew the Quick Clear cartridg e to remove. Discard empty Qui c k Clear
cartridge after use, it is not reusable or refillable.
8. Unscrew the Quick Clear adapter to remove.
Use caution when removing Quick Clear adapter and cartridge, as
some compr e ssed air may com e out at this tim e.
Rememb er to keep the Quick Clear adapter for future use.
9. Replace Easy Quick Clear Valve protective cap, and proceed
with normal start up of your trap. If use of Easy Quick Clear valve
feature does not resolve starting trouble, contact Customer Care
1-877 -224-1538 .
Step 4
First hand-screw the Quick Clear adapter onto the valve.
Step 5
While holding the adapter in place, screw the Quick Clear
cartridge into Quick Clear adapter.
Step 6
To start cleaning process, while holding Quick Clear
Adapter in place, unscrew the Quick Clear cartridge
1/4 Turn Only.
Step 7
Unscrew the Quick Clear cartridge first, then unscrew Quick
Clear adapter and discard the spent Quick Clear cartridge.
Remember to keep the Quick Clear adapter for future use.
14
Tabla de contenido
loading

Productos relacionados para Mosquito Magnet Commander

Tabla de contenido