Technical Data:
Type
Reservoir capacity
Working pressure
Delivery
Weight without
accessories
Motor:
Connection voltage
Motor rating:
Enclosure Class:
Lubricants:
Greases of NLGI Classes 000 to 3 to DIN 51818) can be used.
Pastes with no lubricating properties (with an abrasive content) or silicon pastes must not be used.
Putting into service:
-
Fix the high-pressure hose, with Z-swivel joint and lubrication gun, to the Lube-Compressor.
Release the clamp on the cover and open the reservoir.
-
Put the grease into the reservoir.
-
F
Ensure that the unit is switched off whilst filling and that no contamination can get into the
reservoir.
The Lube-Compressor is now ready for use.
-
F
Before putting the unit into service, check all connections for firm seating and leaks..
Switch on the Lube-Compressor and, with the lubrication gun opened, let it run until grease comes
-
out of the nozzle of the lubrication gun.
The Lube-Compressor should be topped up with grease before the reservoir is completely empty,
-
to avoid unnecessary air getting into the pump system.
-
If however there should be an interruption to the delivery of grease due to air in the pump system,
see the „Notes on malfunctions"
F
Always comply with the Safety Instructions.
Notes on malfunctions:
No grease is being delivered even though the Lube-Compressor is running and the lubrication gun is
opened.
The reservoir is empty and needs to be refilled. (see Putting into Service)
-
There is air in the pump system, which cannot escape through the high-pressure hose.
-
With the pump switched off, disconnect the hose union on the Lube-Compressor and let the unit
run without the hose until grease is pumped out of the hose connector union. Then refit the high-
pressure hose onto the Lube-Compressor.
ELC 6
ELC 6
230 V
400 V
6.3 kg
350 bar
ca. 150 ccm/min.
22.5 kg
230V
400V
AC
3-phase
0.37 KW
IP 54
ELC 15
ELC 15
230 V
400 V
15 kg
300 bar
ca. 150 ccm/min.
33 kg
230V
400V
AC
3-phase
0.37 KW
IP 54
ELC 30
ELC 30
230 V
400 V
30 kg
300 bar
ca. 150 ccm/min.
34 kg
230V
400V
AC
3-phase
0.37 KW
IP 54
loading

Este manual también es adecuado para:

Elc15Elc30