4. Remove the packaging from the fi lter cartridges. Install the cartridges into the fi lter manifold
by lining up the ports and rotating clockwise to lock them in.
NOTE: Remove black rubber plugs from fi lter ports before installing.
NOTE: Stage 1 (PP fi lter cartridge) is the left side of the manifold near the manifold inlet.
UF
5. Locate a position under the sink to mount the fi lter system.
NOTE: The system requires a 75mm space at the bottom for fi lter cartridge replacement.
NOTE: Horizontal mounting of the fi lter manifold is required.
NOTE: Allow space on the right and left side for the tubing to connecting without becoming pinched.
6. Measure and mark the locations for the drill holes. The minimum distance from the cabinet fl oor
to the center of the holes is 50mm. The horizontal distance between hole centers is 120mm
for EFC22 system and 239mm for EFU23/EFU23D systems.
7. Drill the holes using the 6mm drill bit and drill. Install the anchors and screws.
NOTE: Allow 3mm between the screw head and anchor for the fi lter manifold bracket to hang.
EFU23-A Shown
Bottom View
of Filter Manifold
MS
EFC22-A
EFU23-A, EFU23D-A
Page 5
PP
1000003973 (Rev. A - 05/17)