PROBLEM
Cultivator stops while
tilling.
28
CULTIVATOR ATTACHMENT — CTA9500/CTA9500-FC
CAUSE
The motor is
overloaded.
The battery pack or the
power head is too hot.
The blades are jammed.
The battery pack is
disconnected from the
tool.
The battery pack is
depleted.
SOLUTION
The motor will
recover when the
load is removed. For
continuous work,
decrease the load on
the cultivator and avoid
deep tilling; instead,
make progressively
deeper cuts.
Allow the battery pack
or the power head
to cool until the its
temperature drops
below 152°F (67°C).
Remove the battery
from the power head,
manually rotate the
blades back and forth
to remove the stones
or other obstacles
between the blades or
between the blade and
the gear box.
Re-install the battery
pack.
Charge the battery pack
with an EGO charger
listed in this manual.