Area Of Application - Bühler technologies MDS Guía Rápida

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8
MDS
1 Introduction
This quick guide will assist you in starting up the unit. Follow
the safety notices or injury to health or property damage may
occur. Carefully read the original operating instructions in-
cluding information on maintenance and troubleshooting
prior to startup. These are located on the included CD and on-
line at
www.buehler-technologies.com
Please direct any questions to:
Bühler Technologies GmbH
Harkortstraße 29
40880 Ratingen
Germany
Tel.: +49 (0) 21 02 / 49 89-0
Fax: +49 (0) 21 02 / 49 89-20
These operating instructions are a part of the equipment. The
manufacturer reserves the right to change performance-, spe-
cification- or technical data without prior notice. Please keep
these instructions for future reference.
1.1 Intended Use
The operating instructions apply to MDSxxx series mechanical
pressure switches.
The pressure switches are used to monitor the pressure in a
fluid system under normal ambient conditions. As elec-
tromechanical signal converter they convert the pressure into
electrical signals with high precision. They detect pressure
ranges from 0.5 bar to max. 320 bar in different combinations.
Depending on the version, the process connection is a G1/8" or
G1/4" external thread, a G1/4" internal thread, or a flange (VF).
They connect to power via M3 cubic plug (DIN EN 175301-803)
or M12x1 plug (electric line box not included).
1.2 Contents
• MDS Mechanical Pressure Switch
• Product Documentation
2 Safety instructions
The equipment must be installed by a professional familiar
with the safety requirements and risks.
Be sure to observe the safety regulations and generally applic-
able rules of technology relevant for the installation site. Pre-
vent malfunctions and avoid personal injuries and property
damage.
The operator of the system must ensure:
• Safety notices and operating instructions are available
and observed,
• The respective national accident prevention regulations
are observed,
• The permissible data and operational conditions are
maintained,
• Safety guards are used and mandatory maintenance is
performed,
• Legal regulations are observed during disposal,
• compliance with national installation regulations.
4
Bühler Technologies GmbH
3 Transport and storage
Only transport the product inside the original packaging or a
suitable alternative.
The equipment must be protected from moisture and heat
when not in use. It must be stored in a covered, dry, dust-free
room at room temperature.
4 Installation and connection

4.1 Area of application

WARNING
All device models are solely intended for industrial applica-
tions. They are not safety components. The devices must not
be used if failure or malfunction thereof jeopardises the
safety and health of persons.
Use in explosive areas is prohibited.
DANGER
Explosion hazard when used in Ex explosive areas
Use in explosive areas is prohibited.
Before installing the device, please verify the listed technical
data meet the application parameters. Further verify all con-
tents are complete.
4.2 Installation
The device must be connected and installed by a trained pro-
fessional. Always observe the applicable safety regulations for
the operating site!
DANGER
Electric voltage
Risk of electric shock
a) Disconnect all poles of the unit from the mains for any
maintenance on electric components.
b) Secure the equipment from accidental restarting.
c) The unit may only be opened by trained, competent per-
sonnel.
d) Ensure the correct voltages supply.
WARNING
Gases or liquids discharged under pressure
Depressurise the system before installing or removing the
pressure switch.
BX130006 ◦ 03/2019
Tabla de contenido
loading

Este manual también es adecuado para:

MdsmMdsk

Tabla de contenido