Turn the pump on from the control panel. Press the lever
on the wand and spray until there is no air coming out with
the water. This takes approximately 2-3 minutes. Turn the
pump off.

MACHINE OPERATION

Read all instructions before using
this machine.
PRE-SPRAY CARPET
With the use of a pump-up sprayer, pre-spray the carpet with an
approved cleaning detergent. Only use commercially available
mixing and handling instructions on detergent bottle.
combustible material or work in areas were they may be
present.
SET TEMPERATURE AND PRESSURE
1.
While the trigger is activated on the wand and the pump is
turned on (spray should be coming out of the wand), turn
to the desired pressure (50-500 PSI).
Tennant EH5 (01/2014)
Pump
Switch
2.
Select the high heat II or low heat I position on the heater
switch on the control panel. Wait two minutes for the
heater to reach operating temperature.
Note: The heater holds a small amount of water. To maintain
short periods and then stop spraying during a recovery stroke.
Continuous spraying will prevent the water from reaching
maximum water temperature.
CARPET CLEANING WITH WAND
1.
2.
Verify the vacuum hose and solution hose are securely
connected to the machine and wand.
3.
Turn on the pump, vacuum, and heater switches.
Vacuum
Switchs
4.
For optimum cleaning results it is suggested to use a V
stroke pattern as shown. Start with an area approximately
4' x 4'. On the back stroke pull the trigger on the wand for
the solution to spray.