1
WIRING LOCATIONS
Determine the exact location of the vent hood.
• Locate the template packed with the literature.
– Measure 36" from the floor to the top of the cook-
ing surface. Add hood installation height deter-
mined on previous pages. Mark that location.
– Use a level to draw a straight pencil line on the
Wall.
– Tape the template in position along the penciled
line. CHECK TO BE SURE THE TEMPLATE IS LEVEL.
31-10750
02-10 GE
HOUSE WIRING LOCATION:
• The junction box is located on the top right side of
the hood.
• Wiring can enter the cabinet from the ceiling or
from the back wall.
• Route additional wiring length to reach the junction
box.
Installation Instructions
INSTALLATION – RECIRCULATING
Sup # 270-025
2 WALL AND CABINET PREPARATION
IMPORTANT —
to the cabinet and at least two wall studs and
drywall with anchors. Cabinet must be capable of
supporting 100 lbs.
• With the template taped in place, use a punch to
mark all mounting screw locations and electrical
holes according to your application.
• Drill a minimum 3/4" hole for electrical cable in
bottom of the cabinet.
• Drill 1/8" pilot holes at the 4 punched locations on
the bottom of the cabinet.
• Drill 1/8" pilot holes at the 4 punched locations on
the wall
• Remove the template.
• Enlarge holes that did not enter studs to 5/16".
Tap anchors for wall fasteners into the holes.
Cabinet template
REFERENCE - RISER PANEL TOP SURFACE
REFERENCE - CHASSIS TOP SURFACE
PILOT HOLES DRILL 1/8" FOR STUDS
13-3/8"
PILOT HOLES 5/16" FOR ANCHORS
31-10750
BOTTOM OF THE HOOD
02-10 GE
Wall template
NOTE: It is important to engage the wall
studs with at least two screws. Use the
holes which align with the studs.
15
The vent hood must be secured
Cabinet mounting
screw locations
7-1/16"
WALL MOUNTING HOLES
IT IS IMPORTANT TO ENGAGE
WALL STUDS WITH AT LEAST
TWO SCREWS. USE HOLES
THAT ALIGN WITH STUDS.
Sup # 270-025
Wall mounting
screw locations