5.3
SRXL output
The pin header is connected 1:1 to the SRXL input.
You can connect other SRXL-compatible devices. For
example,
you
can
MULTIswitch FLEXX or connect an SRXL-compatible
stabilisation system.
5.4
LED display
The LED will light up as soon as the MULTIswitch FLEXX
receives the correct data from a remote control receiver or
a PC.
5.5
Jumper U(Bat) / U(Bat)
Jumper U(Bat) connected
When the jumper is connected, the operating voltages of
the MULTIswitch FLEX electronics, the remote control
system and the loads are connected with each other.
In this case, a single voltage source is sufficient to supply
the power. This may be a receiver battery that is
connected to the remote control receiver.
Alternatively, you can use any voltage source that is
connected to the terminal U(Bat).
!
Damage due to excessive voltage: Make sure
that the voltage does not exceed 12 volts (3S
LiPo
battery).
When
connected, the maximum operating voltage for
ALL connected components (loads, receiver,
servos)
must
This is usually a maximum of 6 volts for standard
servos.
Receiver battery
Remote control
receiver
SRXL
Servo
Figure 2 Example of jumper U(Bat) connected
MULTIPLEX Modellsport GmbH & Co.KG • Westliche Gewerbestraße 1 • D-75015 Bretten (Gölshausen) • www.multiplex-rc.de
Operating Instructions
MULTIswitch FLEXX
create
a
chain
with
the
jumper
U(Bat)
not
be
exceeded.
several
Remote control
receiver
SRXL
Servo
Figure 3 Example of jumper U(Bat) connected (alternative)
5.6
Jumper U(Bat) / U(Bat)
Jumper U(Bat) disconnected
When the jumper is disconnected, the loads can be
supplied separately via the terminal U(Bat).
In this case, the MULTIswitch FLEXX electronics and the
receiver require their own power supply, e.g. a receiver
battery.
!
Damage due to excessive voltage: Make sure
that the voltage for the loads does not exceed 12
volts
The permissible voltage range of the individual
is
loads must not be exceeded.
Receiver battery
Remote control
receiver
SRXL
Servo
Figure 4 Example of jumper U(Bat) disconnected
Receiver
battery
(3S
LiPo
Voltage source
for loads
battery).
Page 2/4