Congratulations on your decision to purchase the NEOS
III ensemble.
This manual contains the necessary instructions for the
correct installation of the NEOS III hydromassage col-
umn.
Installation must be completed by an qualificated fitter
and in accordance with existing regulations.

1. DESCRIPTION OF THE EQUIPMENT

1.1. NEOS III (Page 15)
1.2. FITTINGS BOX (Page 15)
1.2.1. WALL INSTALLATION (Pág. 15)
1.2.2. CORNER INSTALLATION
(Kit adicional 2H0364000) (Pág. 16)
1.3. SHOWER UPPER (Páge. 16)
2. MATERIALS NEEDED FOR THE INSTA-
LLATION
(Page 16)
3. PRELIMINARIES
Person measure X : (Page 16)
The water outlets from the plumbing system must be at the
intended location. (Fig. 1-1a). (Page 17)
The wall area against which the column is to be fi tted must
be adequately fi nished and completely fl at. Take care to avoid
shaped relief tiles, decorative friezes or projections of any kind.
- Type of water: drinking.
If the dynamic pressure is 5 bars or more, it is necessary to
purchase the pressure reducer kit (ref. 2HF086000).
Accumulator tanks:
If the hydromassage is going to be supplied from an accu-
mulator tank with a capacity of less than 100 litres, we re-
commend that you turn the thermostat to the highest possible
temperature setting. Otherwise the supply of hot water is only
likely to last for a few minutes when the hydromassage is in
operation. For safety reasons a temperature of 60°C. must not
be exceeded.
(Page 16)
Instant heaters:
If using an instant heater or combination boiler, they must guar-
antee the pressure and consumption levels stated above.
If the output power is less than 20,000 Kcal/hour, high tem-
peratures cannot be maintained during certain functions, and
a loss of pressure or temperature will be noted.
If the boiler switches off and cold water comes out, first clean
the filters of the thermostatic taps, and if the problem con-
tinues, adjust the temperature and the flow of the boiler as
required. If you do not manage to solve the problem, please
consult the boiler's after-sale service.
Mixed systems with an instant heater and an accumulator
tank:
This is the recommended system, with a tank volume of no
less than 50 litres.
4. INSTALLATION
5. OPERATING INSTRUCTIONS
Position the thermostatic tap at 38ºC and check if the water
comes out at this temperature. If this is not case, proceed os
follows Fig. 2
The inverter switch on the hydromassage column (Fig. 3) allo-
ws you to select the following functions:
Simply turn the inverter switch towards the desired position,
moving it in either direction, even when the water is running.
Using the riser single-lever tap, the desired water temperatu-
re and fl ow for each function can be chosen.
To adjust the flow from the jets, since these can be moved, turn
them towards the optimum position as required. The type of
massage can be selected in the same way, with independent
adjustments for the power and type of spray from each jet.
The shower head has a multifunctional sprinkler, and the type
of spray or preferred massage can be selected by turning the
outer ring on the head (Fig. 3).
5
(Page 17- 24)
Hand-held shower
Shower Upper
Upper hydromassage jet
Central hydromassage jet
Lower hydromassage jet