3200Pb1Z-Prefeed Motor Parameter Settings - Atlanta Attachment Company 3200PB1Z Manual Técnico & Lista De Partes

Tabla de contenido

3200PB1Z-Prefeed Motor Parameter Settings

Before Programming, Perform a Master Reset of Parameters (See Below)
PARAMETER
RANGE
290
026
121
300>
111
0-999
119
153
0-50
161
207
1-55
220
1-55
240
0-56
270
272
020-255
436
401
Front panel LED's:
LED 1: Off
LED 2: Off
LED 3: Off
LED 4: Off
LED 5: Off
LED 6: Off
LED 7: Off, Stop at needle down.
LED 8: Off
Speed
Fast
Slow
VALUE
0
0
300
0310
1-3
1
0
0-1
1-CCW
1
1
55
0-5
5
1000
0
1
Programming Instructions:
1. Power on holding down the "P" button till "CODE" is displayed.
2. Press ">>" once and enter the number "5913"
3. Press "E" once and "4.0.0." is displayed this is a parameter
4. Proceed to the parameter to be changed and press "E"
5. The value now shows in the screen, adjust to desired value.
6. Press "E" to enter value and continue with parameter setting.
7. Repeat for other parameters, press "P" once when complete.
8. Run sewing head to save parameters before powering down
To Perform Master Reset of Parameters:
1. Power on holding down the "P" button till "CODE" is displayed.
2. Press ">>" once and enter the number "5913"
3. Press "E" twice and "093" is displayed.
4. Press "+" once, "094" is displayed.
5. Press "P" to exit programming mode with all default values.
RPM
Treadle/Low
95
C
95
A, C
DESCRIPTION
Mode of operation. MUST SET THIS PARAMETER
FIRST!
Lower limit for Par 111 (must set before 111)
Maximum speed when "129" is 0, 1, or 2.
Linear acceleration
Braking power at standstill
Motor rotation
Braking
Acceleration
Enable reverse run of motor with input 1
No handwheel sensor
Drive ratio between motor pulley and handwheel pulley. If
handwheel pulley is smaller than motor pulley, increase
this value to slow down sewing head until measured
speed matches speed set with parameter 111.
Technical Manual & Parts Lists
18
Tabla de contenido
loading

Tabla de contenido