Fix the rear cover to the wall using the supplied screws and wall plugs. Do not over-tighten the fixing
screws as this may distort or damage the cover.
3.
Replace the main body to the rear cover and refit the fixing screw in the bottom of the PIR to secure
the main body. Do not over-tighten the fixing screw as this may damage the casing.
Operation
When the detector is mounted on the wall i.e. tamper switch is pressed for more than 10 seconds, it will
enter Normal mode.
- Upon motion being detected, the detector will send an alert signal to the controller and enter
sleep state for a preset period to conserve battery life. It will only be able to detect motion again
when this preset period is up. This preset period is called Retrigger Interval and can be set by the
controller. The default period is 3 minutes.
- Unlike in Test mode, the red indicator LED on the detector will not illuminate when triggered in
order to conserve battery life. However when the battery becomes low the LED will flash
whenever motion is detected to alert the user to replace its battery.
The detector can provide periodic auto report measurement of temperature and humidity to the
controller, or on demand when requested by the controller.
In the event its front cover is removed, the tamper switch will be activated and the detector will send a
Notification command to the controller.
Maintenance
Low Battery: When the battery becomes low, the LED will flash red when motion is detected to indicate
low battery condition to the user. Replace the batteries as soon as possible.
Troubleshooting
The troubleshooting table lists some possible causes and solutions. Please contact your original retailer
or nearest service center if the below solutions cannot solve your problem.
Symptom
Cause of Failure
LED cannot be displayed
1. Run out of battery power.
2. Check if reverse battery
polarity.
The detector is not working
1. The PIR detector cannot
communicate with the
gateway HSC04.
2. Check if the detector is out of
order.
After the one-minute warm up is
Check if detector has
completed, the detector does not
completed binding with
work and LED flashes on and off
Homesys Gateway
repeatedly at with an interval of 2
seconds
Reset to Factory Settings
1.
2.
Specifications
Battery
Operating Temperature
PIR Warm Up Time
PIR Detection Coverage
PIR Pet Immunity
Operating Frequency
** Specifications are subject to change without notice.
WARNING:
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact your local government for information regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the
groundwater and get into the food chain, damaging your health and well-being.
When replacing old appliances with new ones, the retailer is legally obligated to take back your old
appliance for disposal at least for free of charge.
www.everspring.com
3F., No. 50, Sec 1, Zhonghua Rd., Tucheng Dist.,
Recommendation
New Taipei City 23666, R.O.C
1. Replace a new battery.
2. Refit the battery with correct
polarity.
1. Place the PIR Detector closer to
the gateway.
2. Send the device in for repair and
do not open it.
Remove the battery and follow
the steps for "Manual binding".
4
Press and hold the Link button on the PCB for 3 or more seconds, and the detector LED will start
to flash.
Press and hold the Link button for 6 or more seconds within 30 seconds until the LED turns off.
The device is now reset back to factory mode
CR123A Lithium Battery
-10°C to 40°C
About 1 minute
Wall-Mounted:
Up to 12m x 90° (at 2m mounting height & 25°C)
Height≦ 60cm; Length≦ 90cm
868MHz (EU)/ 923MHz (America)