Changing Between Fahrenheit and Celsius
1. Make sure the unit is in standby mode. Refer to the
"Standby Shutdown" procedure in this section.
2. Press and hold the
• The LED display will show either "F" or "C" to indicate the
active unit of measure.
Adjusting the Temperature Setting
NOTE: If the
buttons are not pressed within three
seconds during programming, the unit will revert to
showing the current timer setting without making any
changes.
1. With the unit in operating mode, press the
• The LED display will show the current setpoint
temperature.
2. Press the
or
button to increase or decrease the
setting to the desired setpoint temperature.
3. After eight seconds of inactivity:
• The unit will accept the new setting.
• The LED display will change to show the current
temperature of the unit while it adjusts to the new
setpoint temperature.
4. When temperature adjustment is complete, the LED display
will show the current timer setting.
NOTE: The unit will operate normally during the temperature
adjustment period after a setpoint temperature change.
Form No. WMCEM-0519
button for three seconds.
button.
Adjusting the Timer Setting
NOTE: If the
buttons are not pressed within three
seconds during programming, the unit will revert to
showing the current timer setting without making any
changes.
1. With the unit in operating mode, press the
times.
• The two characters that represent "minutes" will flash on
the LED display.
2. Press the
or
setting to the desired number of minutes.
3. Press the
button.
• The two characters that represent "seconds" will flash on
the LED display.
4. Press the
or
setting to the desired number of seconds.
5. After eight seconds of inactivity:
• The unit will accept the new setting.
• The LED display will change to show the new current
timer setting.
9
OPERATION
button to increase or decrease the
button to increase or decrease the
button two