Fast Ethernet Switch LED Panel
LED
PWR
(Power)
LNK/ACT
(Link/Activity)
SPEED
(1000/100/10M)
1. Operating Environment
This switching hub must be installed and operated within the limits of specified operating
temperature (32-131°F) and humidity (10~95% Non-condensing).
Do not place objects on top of the unit.
Do not obstruct any vents at the sides of the unit.
Do not position the unit near any heating source such as heater, radiator, or direct
exposure to sun.
Prevent entering of water and moisture into the unit. If necessary, use dehumidifier to
reduce humidity.
2. Connecting to network devices
The RJ-45 ports on the switch support Auto-MDI/MDI-X function which allows using
straight-through or cross-over type cables to connect this switch to workstation or hub.
Connect one end of the network cable to the RJ-45 port on the rear panel, and connect
the other end of the network cable to the RJ-45 port on the network device. Follow the
same procedure to connect all the RJ-45 ports of the switch.
The UTP network cables must comply with EIA/TIA 568 specifications and Category 5
standard for 100Mbps data transmission. Maximum length: using UTP cable, between
the switch and connected device is 100 meters (300ft).
Once the network cable is connected to both ends and the attached network device is
powered on, the green LNK/ACT LED should be lit.
Color
Status
Lit
Green
Off
Lit
Green
Flash
Off
Off
Green
Orange
This port run at 1000Mbps
3
Description
The switch is powered on
The switch is powered on
A valid link is established
Data packets received
No link is established
This port run at 10Mbps
This port run at 100Mbps