Technical Data

Code
Description
Voltage
Frequency
Current
Power
Speed
Cuts per minute
Dust Collecting
System
Duty Cycle
Conductores
Insulating
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING

Power Requirements

WARNING
Tools with double insulation and reinforced insulation are
equipped with a polarized plug (one prong is wider than the other). This plug will
only fit in the right way into a polarized outlet. If the plug cannot be introduced into
the outlet, reverse the plug. If it still doesn't fit, call a qualified electrician to install
for you a polarized outlet. Do not alter the plug in any way. Both types of insulation
eliminate the need of both a grounded third power cord with three prongs or a
grounded power connection.
WARNING
When using an extension cable, verify the gauge is enough for the power that your product needs. A lower gauge cable will
cause voltage drop in the line, resulting in power loss and overheating. The following table shows the right size to use
depending on cable's length and the ampere capability shown in the tool's nameplate. When in doubt use the next higher
gauge.
Ampere
Capacity
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
WARNING
When operating power tools outdoors, use a
extension cable labeled "For Outdoors Use". These extensions are especially designed for
operating outdoors and reduce the risk of electric shock.
50 minutes' work per 20 minutes' idle. Maximum 6 hours per day.
Class II
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge - Reference NMX - J - 195 - ANCE - 2006
CEPEL-3-1/4N
13442
Electric Planer
120 V
60 Hz
6 A
720 W
16 000 RPM
32 000 cuts/min
Left-Right
18 AWG x 2C with 158 °F insulating temperature.
IP Grade
Power cord grips used in this product: Type "Y".
Build quality: Reinforced insulation.
Thermal insulation on motor winding: Class A
Extension Gauge
From 6 ft to 49 ft
18 AWG
16 AWG
14 AWG
8 AWG
IP20
Authorized Service Center.
|
Higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
grounded