DESCRIPTION
The Two Hand Anti Tie Down Control unit is suited for industrial machines where
it is desirable to monitor the position of the operator's hands throughout the haz
ardous portion of the machine cycle. This two hand anti tie down valve is a pneu
matic, flange type, unitized control circuit designed to require a machine operator
to push both button controls at the same time in order to produce an output signal
to the machine. The operator must hold the button controls in the pushed position
in order to maintain this output signal. If either push button control is released, in
dicating that the operator's hand is no longer in contact with it, the signal ends and
is exhausted. The signal can only be restarted by releasing both button controls
and pushing them again at the same time. This two hand anti tie down valve pre
vents the operator from tying down one of the button controls and activating the
output only with the other.
SPECIFICATIONS
Model:
59191
Description:
Pneumatic Two Hand Anti Tie Down
Logic Asm.
Logic Function:
2 Inputs at the same time produces the output.
If either input goes off, the output goes off.
Media:
Use with Compressed Air Only
Connections:
Two 1/8'' NPTF Inputs, One 1/8'' NPTF Output
Maximum Temperature:
+32_F to +160_F
Filtration required:
40 Micron, clean, dry
Lubrication:
Not Required
Operating Range (Max):
50 to 125 p.s.i.g.(3.4 to 8.6 bar)
Flow:
4 SCFM max. usable output at
100 P.S.I.G (6.9 bar)
Pressure Regulation:
As required to actuate the power device
INGERSOLL-RAND COMPANY
P.O. BOX 151
&
(419) 636-4242
PNEUMATIC TWO HAND
ANTI-TIE-DOWN ASM.
ENSAMBLADURA DE CONTROL NEUMÁTICO
ANTI SUJECIÓN PARA DOS MANOS
PNEUMATIQUE À DEUX MAINS AVEC
DISPOSITIF ANTI VERROUILLAGE
DE BOUTON DÉCLENCHEUR ASM
2" (50.8 mm)
1/8 N.P.T.F.
(3)
1" (25.4 mm)
2 1/2" (63.5 mm)
MOUNTING HOLES FOR NO. 10 SCREWS
AGUJEROS DE INSTALACIÓN PARA TORNILLOS DEL NO.10
TROUS DE MONTAGE POUR VIS NO 10
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
ONE ARO CENTER
BRYAN, OHIO 43506 0151
D
D
D
E
FAX (419) 633-1674
2000 D PRINTED IN U.S.A.
REVISED / REVISADO / REVISE:
1/4" (6.4 mm)
NOT FIELD REPAIRABLE – For repair information,
contact the ARO service department.
WARNING DO NOT USE THIS TWO HAND ANTI TIE DOWN
VALVE WITH ANY TYPE OF REVOLUTIONARY PRESS. This
anti tie down valve only provides the anti tie down logic func
tion and is not a single cycle limiting device. Where repeat
cycles can occur, a single cycle limiting device must be used
together with this anti tie down valve.
A filtered, non lubricated air supply must be used with this
anti tie down valve.
Failure to follow this warning could cause serious injury.
INSTALLATION
Note: Be sure filter screens are properly positioned in input ports before installing
this device. These screens are factory installed and provide added protection
against contaminants getting into the control unit.
MODEL / MODELO / MODÈLE
59191
7-14-00
59191
loading

Resumen de contenidos para Ingersoll Rand ARO 59191

  • Página 1 OPERATOR’S MANUAL MANUAL DEL OPERATOR’S PNEUMATIC TWO HAND MODEL / MODELO / MODÈLE 59191 MANUEL DE L’UTILISATEUR ANTI-TIE-DOWN ASM. ARO PNEUMATIC LOGIC CONTROL ENSAMBLADURA DE CONTROL NEUMÁTICO LOGIC FUNCTION ASSEMBLY ANTI SUJECIÓN PARA DOS MANOS CONTROL LÓGICO NEUMÁTICO ARO PNEUMATIQUE À DEUX MAINS AVEC ENSAMBLADURA DE FUNCIONES LÓGICAS DISPOSITIF ANTI VERROUILLAGE COMMANDE LOGIQUE PNEUMATIQUE ARO...
  • Página 2 LIRE ATTENTIVEMENT CE LEA CUIDADOSAMENTE ESTE MANUEL AVANT D’INSTALLER, MANUAL ANTES DE INSTALAR D’UTILISER OU DE REPARER ESTE EQUIPO, OPERARLO O CET APPAREIL. REALIZARLE SERVICIO. Il incombe à l'employeur de s'assurer que ces informations seront El empresario tiene la responsabilidad de poner esta información en lues par l'opérateur.
  • Página 3 SYSTEM VIEW / VISTAZO DEL SISTEMA / VUE DU SYSTÈME 3 WAY PALM VALVE PILOT OPERATED POWER VALVE 4 WAY / SPRING RETURN VÁLVULA DE CARA PLANA DE 3 VÍAS (NOT INCLUDED IN PACKAGE) CLAPET 3 VOIES ACTIONNÉS PAR LA PAUME VÁLVULA DE PODER PILOTADA PORT IDENTIFICATION 4 VÍAS / RETROCESO POR MUELLE...
  • Página 4 59809 CONTROL ASSEMBLY 59808 CONTROL ASSEMBLY ENSAMBLAJE DE CONTROL 59809 ENSAMBLAJE DE CONTROL 59808 UNITÉ DE COMMANDE 59809 UNITÉ DE COMMANDE 59808 30" (762 mm) OUTPUT SIGNAL SEÑAL DE SALIDA SIGNAL DE SORTIE SUPPLY AIR SUMINISTRO DE AIRE OUTPUT SIGNAL AIR D'ALIMENTATION SEÑAL DE SALIDA SIGNAL DE SORTIE...