Checking for Leaks

WARNING
When checking for or repairing leaks or if you smell gas,
extinguish all flames and do not turn on any device that
could cause a spark such as lights, power tools, cooking
appliances or this grill. If you cannot repair the leak, turn
the gas off and call a qualified service technician to repair
the leak.
WARNING
Never use a flame to check for leaks. Doing so may cause
serious injury, property damage or death.
WARNING
If this product maybe damaged using 1/2 psig or more during
test it must be disconnected.
After installing the grill or after any service or repair you must
check all gas connections for leaks.
Spray or brush a solution of 50% water and 50% liquid soap on
to all gas connections and the valve. Make sure the gas is turned
on and wait up to five minutes. If bubbles appear there is a leak.
To repair the leak, tighten the connection. If the leak persists,
shut off the gas and get a qualified service technician to
repair the leak. Liquefied Petroleum (LP) has an odorant
added to the gas. If you smell an odor, you may have a gas
leak. Follow the leak check instructions above.

Close the Drawer After Use

WARNING
Allow grill to cool to touch before moving or storing. Failure
to do so could result in fire resulting in property damage,
personal injury or death.
1. Remove the warming rack after the grill has cooled for at
least 30 minutes, put it beside the grill.
2. Lift up the splash guards a little, rotate the right splash
guard (a) to the lid first, then rotate the other one (b), use
7
the splash guard holder to secure them together.
b
3. Position the warming rack as shown below on the grate (it
should sit flat on top of the grate), close the lid according to
the arrow direction to close it. Ensure the lid locks into the 2
front slots by firmly pressing down on the lid.
4. Always remove and clean the drip tray after each use (See
page 10).
5. Disconnect the gas supply line and then close the drawer
once the grill has adequately cooled.

Ventilation Requirements

CAUTION
Your grill requires proper ventilation.