1
Manual de instalación
1.12 Rendimientos ARH/ARD
1.12.2 Potencias frigoríficas ARH/ARD 060
Aire de retorno
Caudal
TH
PT
PC
Temp. entrada TS en bateria in‐
ºC
3
m
/h
kW
kW
30
23
69.8
14.2
42.2
(Míni‐
19
63.2
13.7
55.7
mo)
17
59.7
13.4
59.7
9500
15
53.7
13.3
53.7
23
72.4
14.4
46.5
(Nomi‐
19
65.6
14
62.4
nal)
17
61.9
13.7
61.9
11500
15
55.7
13.5
55.7
23
74.4
14.6
50.7
(Máxi‐
19
67.4
14.2
67.4
mo)
17
63.6
13.9
63.6
13500
15
57.2
13.7
57.2
*
Datos de acuerdo a condiciones del programa de certificación Eurovent para Rooftop.
PT: Potencia total; PC: Potencia absorbida por el compresor.
TH: Temperatura bulbo húmedo; TS: Temperatura bulbo seco.
1.12.3 Potencias frigoríficas ARH/ARD 075
Aire de retorno
Caudal
TH
PT
PC
Temp. entrada TS en bateria in‐
ºC
3
m
/h
kW
kW
30
23
81.1
19.6
49.2
19
73.5
19
65.2
(Mínimo)
11500
17
69.3
18.5
69.3
15
62.4
18.3
62.4
23
83.5
19.9
53.3
(Nomi‐
19
75.7
19.2
71.6
nal)
17
71.4
18.8
71.4
13500
15
64.2
18.6
64.2
23
85.9
20.1
58.3
(Máxi‐
19
77.8
19.5
77.8
mo)
17
73.4
19.1
73.4
16000
15
66.1
18.9
66.1
*
Datos de acuerdo a condiciones del programa de certificación Eurovent para Rooftop.
PT: Potencia total; PC: Potencia absorbida por el compresor.
TH: Temperatura bulbo húmedo; TS: Temperatura bulbo seco.
18
Temperatura del aire en la batería exterior (TS)
27 ºC
Potencia sensible kW
PT
PC
terior
kW
kW
27
24
22
33.1
24.1
-
66.3
15.5
46.7
37.7
31.6
59.7
14.9
53.3
44.3
42.5
54.9
14.8
53.7
49.3
43.3
51.3
14.5
35.8
25
-
68.7
15.8
51.7
41
33.8
61.9*
15.2*
59.5
48.7
48.1
56.9
15
55.7
55
47.8
53.2
14.7
38.2
25.8
-
70.6
16
56.5
44.1
35.8
63.6
15.4
63.6
53
53
58.5
15.2
57.2
57.2
52.1
54.7
14.9
Temperatura del aire en la batería exterior (TS)
27 ºC
Potencia sensible kW
PT
PC
terior
kW
kW
27
24
22
38.6
28
-
76.9
21.4
54.6
43.9
36.8
69.3
20.6
62.2
51.7
52
63.8
20.4
62.4
57.6
50.5
59.6
20
41.1
28.9
-
79.3
21.7
59.3
47.1
38.9
71.4*
20.9*
68.2
55.9
58
65.7
20.7
64.2
63
54.8
61.4
20.3
44
29.8
-
81.5
22
65
50.7
41.3
73.4
21.2
73.4
61
60.6
67.5
21
66.1
66.1
60
63.1
20.6
35 ºC
Potencia sensible kW
Temp. entrada TS en bateria in‐
PT
terior
kW
30
27
24
22
40.9
31.9
22.8
-
59.7
54.3
45.2
36.3
30.2
53.7
54.9
51
42
38.3
48.9
51.3
51.3
48
42
46
45.2
34.5
23.8
-
61.9
61
50.3*
39.5
32.4
55.7
56.9
56.9
46.5
42.5
50.8
53.2
53.2
53.2
46.5
47.7
49.4
37
24.6
-
63.6
63.6
55.1
42.6
34.3
57.2
58.5
58.5
50.8
46.6
52.1
54.7
54.7
54.7
50.8
49
35 ºC
Potencia sensible kW
Temp. entrada TS en bateria in‐
PT
terior
kW
30
27
24
22
47.8
37.2
26.6
-
69.3
63.5
52.9
42.3
35.2
62.4
63.8
59.7
49.1
46
56.8
59.6
59.6
53.1
49.1
53.3
51.9
39.6
27.4
-
71.4
69.9
57.6*
45.4
37.2
64.3
65.7
65.5
53.3
50.3
58.5
61.4
61.4
61.4
53.3
55
56.8
42.6
28.3
-
73.4
73.4
63.3
49
39.6
66.1
67.5
67.5
58.4
55.5
60.2
63.1
63.1
63.1
58.4
56.5
46 ºC
Potencia sensible kW
PC
Temp. entrada TS en bateria in‐
kW
terior
30
27
24
22
17.1
38.8
29.8
20.7
-
16.1
52.1
43
34
28
15.9
49
48.7
36.7
33.6
15.8
46
46
45.8
39.8
17.5
43.2
32.4
21.7
-
16.4
55.7
48
37.3
30.1
16.3
50.8
50.8
44.1
36.9
16.1
47.7
47.7
47.7
44.2
17.7
47.3
34.9
22.5
-
16.6
57.2
52.8
40.2
32.1
16.5
52.1
52.1
48.3
40
16.3
49
49
49
48.6
46 ºC
Potencia sensible kW
PC
Temp. entrada TS en bateria in‐
kW
terior
30
27
24
22
23.7
45.4
34.8
24.1
-
22.2
61
50.3
39.7
32.6
22
56.8
56.8
46.3
39.3
21.8
53.3
53.3
53.3
46.5
24
49.5
37.2
25
-
22.6
64.3
55.1
42.8
34.7
22.4
58.5
58.5
50.6
42.4
22.2
55
55
55
50.7
24.4
54.4
40.2
25.9
-
22.9
66.1
60.7
46.5
37
22.7
60.2
60.2
55.6
46.1
22.5
56.5
56.5
56.5
55.8