SPRING REPLACEMENT INSTRUCTIONS
Turn off the iron and unplug it, ensuring it has cooled
completely before replacing the spring.
1. Remove the screws from the barrel: Hold the iron by the
barrel and push down gently on the thumb grip. Use a small
Phillips screwdriver to remove one screw, then the other.
Barrel
2. Remove the old spring from the barrel: Using a small Phillips
screwdriver, gently loosen the screw—a quarter or half turn
counterclockwise should remove the screw. Pinch the spring's
coils together and pull the spring out of the bracket.
3. Insert the new spring: Pinch the new spring's coils together
and insert it into the bracket. Do not push the spring in as far
as it will go, but leave a small portion of the rods extending
from the bracket.
4. Tighten the bracket screw carefully, keeping the new
spring straight on the barrel.
5. Replace the clamp: Holding the iron by the barrel, align the
clamp's screw holes with the screw holes in the barrel. Insert
each screw.
6. Test the clamp several times to ensure the iron works
properly.
Rated Wattage
Rated Voltage(V)
Frequency(Hz)
Weight (g)
Length of A.C. Cord
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING.
DANGER – Any appliance is electrically live, even when the
switch is off. When not in use, always unplug the iron to prevent
the risk of fire.
WARNING – To reduce the risk of burns, electrocution, fire, or
injury to persons and/or personal property:
• Use the iron only for the purpose described in this guide to
prevent accidents, damage or malfunction.
• This appliance should never be left unattended when
plugged in.
• Avoid multiple cables to a plug or use of an extension cord
to prevent starting a fire from overheating.
• KEEP AWAY FROM WATER to prevent fire, electric shock,
damage or malfunction.
• KEEP AWAY FROM CHILDREN.
• Do not handle the iron or cord with wet hands as this may
cause electric shock.
• Do not leave the iron in a position where it can fall or be
pulled into a tub or sink.
• Keep the cord away from heated surfaces.
• DO NOT WRAP THE CORD AROUND THE IRON.
Clamp
Screw
GENERAL SPECIFICATIONS
1" Model GI10NAB20
40W
110-240V
60Hz
285g/ 10.05 oz. (0.62 lbs.)
9ft / 2.7m