INSTALLATION MANUAL FOR IN.28.108
EN
LED INDICATORS
POWER (Red / Yellow)
Red - Normal mode
Flashing lights indicates that the magnetic door sensor is triggered or there is an alarm output.
PROGRAMMING SUMMARY
NOTE:
The numeric keypad has to be in its normal state before entering the programming mode.
Change master code (Default code: 1234)
1
*
1234 1234
00 "M-CODE" #
2x master code
Change user code (Default code for users: 3333)
2
M-CODE M-CODE
2x master code chosen
Change additional user code
3
Ex. User number 45 (20-99)
M-CODE M-CODE
Output operating time (Default time: 5 seconds)
4
M-CODE M-CODE
Delete users
5
M-CODE M-CODE
(User number to delete. Example:45
Operating mode
6
M-CODE M-CODE
M-CODE M-CODE
In the latching mode, the relay willatch allowing free entry until the latching code is re-entered.
6.1) Program the latching modes starting code - Only with direct connection.
M-CODE M-CODE
Restoring system to factory setting
7
Connect with power source. When the green light flash, press #5 at same time.
All settings and codes will be restored to default settings.
Manual de instalação / Installation Manual / Manual de instalación - MI082-2
Yellow - Programming mode
Master code chosen
Ex. User number 01 (01-19)
*
01 "U-CODE" #
User code chosen
*
6 "45" "U-CODE" #
User code chosen
*
20 "TIME" #
(01 - 99 seconds)
*
50 "45" #
00 deletes all users)
*
52 "0" #
*
52 "1" #
*
54 "XXXX" #
(0 = Normal mode)
(1 = Latching mode, by entering the latching code)
(XXXX = Specific code for latching mode)
Green - Activated lock output