Low voltage.
Empty battery symbol flashing means the battery is
discharged lower than the LVD voltage. The BlueSolar
Charge Controller has disabled the output. User should
charge the battery until it is up to LVR Low voltage re-
connect voltage and then BlueSolar Charge Controller will
recover the output status.
Short-circuit protection.
This display means a short-circuit protection occurs. The
BlueSolar Charge Controller will switch off the output and
wait for 30s and then try to recover again. User should
check and remove the trouble in time.
Over-current protection.
This display means an output over-current occurs. The
BlueSolar Charge Controller will switch off the output and
wait for 30s and then try to recover again. User should
check and remove the trouble in time.
Shut down after 60s in case of 110%-130% load.
Shut down after 5s in case of 130%-160% load.