National Instruments USB-6008 Guía De Seguridad Y Uso página 4

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
Signal Name
GND
AI <0..7>
AO <0, 1>
P0.<0..7>
P1.<0..3>
PFI 0
+2.5 V
+5 V
NI USB-6008/6009 Safety and Usage Guide
Reference
Direction
Varies
Input
GND
Output
GND
Input or Output
GND
Input or Output
GND
Input
GND
Output
GND
Output
Ground—The reference point for the single-ended analog input
measurements, analog output voltages, digital signals, +5 VDC supply,
and +2.5 VDC at the I/O connector, and the bias current return point for
differential mode measurements.
Analog Input Channels 0 to 7—For single-ended measurements, each
signal is an analog input voltage channel. For differential measurements,
AI 0 and AI 4 are the positive and negative inputs of differential analog
input channel 0. The following signal pairs also form differential input
channels: <AI 1, AI 5>, <AI 2, AI 6>, and <AI 3, AI 7>.
Analog Output Channels 0 and 1—Supplies the voltage output of
AO channel 0 or AO channel 1.
Port 0 Digital I/O Channels 0 to 7—You can individually configure
each signal as an input or output.
Port 1 Digital I/O Channels 0 to 3—You can individually configure
each signal as an input or output.
PFI 0 —This pin is configurable as either a digital trigger or an event
counter input.
+2.5 V External Reference—Provides a reference for wrap-back
testing.
+5 V Power Source—Provides +5 V power up to 200 mA.