Installation And Use - Beco Technic SANDY Instrucciones De Manejo

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Operating Instruction
GB
Sand blasting machine SANDY
Item.-No.: 313 632
Congratulation for your choice!
Choosing this apparatus you have purchased a particularly reli-
able unit that will facilitate your work.
IMPORTANT: Before installing the apparatus, read carefully this
manual and keep it for future consultations.
Warning
Do follow carefully all the indications brought back in this
manual.
During all the maintenance operations disconnect the power
cord from the electrical outlet, and / or disconnect the com-
pressed air and / or the water attack and / or other attacks of
external parts to the apparatus.
Do not introduce stranger objects inside the unit during the
maintenance operations.
Use only the accessories in equipment for the filling opera-
tions and / or maintenance.
Do not execute different operations of maintenance from
those brought back in the manual. Whichever operation not
contempled in this manual, can involve risks.
For operations of this type, contact the technical service. Be-
fore turning on the unit and connecting the power cord to the
electrical outlet, make sure that the voltage corresponds to the
one brought back on the fabrication nameplate placed on the
back part of the apparatus.
Caution
Do not make any maintenance operation when the power
cord is connected: FULGURATION DANGER!
Use only genuine spare parts. Placing not genuine spare parts
can void your warranty, moreover can make the apparatus not
in compliance with the norms, and dangerous when in use.
For whichever inherent information concerning installation,
maintenance and use of the unit, contact the customers' serv-
ice
Unpack
Verify integrity of the pack at the moment of the reception of
the apparatus.
Verify that in the packaging all the parts and the supplied ac-
cessories of series are contained together with the apparatus.
BIRKENSTOCK & CO. GMBH · D-21500 Geesthacht · Germany ·
Technical changes as well as changes in production and prices are subject to our approval. For our terms of delivery and payment please go to www.beco-professionals.com.
Reg. office: D-21500 Geesthacht · Register Court: Lübeck HRB 314 GE · Managing Directors: Jürgen Birkenstock, Marek Birkenstock · VAT-Number: DE 135283788 · ILN 40 22739 00000 3 · WEEE.Reg.Nr.: DE12990100
Description
Technical Data
Sandblaster Sandy
Dimensions: (W x H x D)
420 x 340 x 350 mm
Weight: 12 kg
Fuses: 2 from 5 x 20 mm from 6.3 Ampere
Microsandblaster absorption 9 Watt;
suction unit AIRBOX GS max 800 Watt.
Operating voltage V/Hz 230 / 50-
60 or 110 / 50 (see nameplate
on the apparatus)
k

Installation and use

ref. = Number of the component given on the enclosed ex-
ploded drawing
Code = Order number of spare part
1
Take the apparatus out of the packaging, and place it on a flat
surface strong enough to bear its weight. Do not place the ap-
paratus close to humidity and / or vapor sources (steam gen-
erators, stoves, windows, etc.).
2
Insert the neon lamp inside of cabin in the appropriate lamp
holder (ref. 33 - 34) making a light pressure.
3
Connect the tube of the compressed air to the connection
placed on one side of the unit - MAX 8 BARS (ref. 28).When
using our suction unit, connect the hose of AIRBOX GS in the
appropriate connection placed on the back side of the unit.
4
Then connect the power cord plug of AIRBOX GS to the outlet
on the right side of the microsandblaster (ref. 37). Now con-
nect the power cord of the microsandblaster to the electrical
outlet in your laboratory.
ATTENTION: make sure that the voltage corresponds to the one
brought back on the fabrication name plate placed on the ap-
paratus. Turning on the main switch of the microsandblaster (ref.
42) will activate all the system. Regulate the aspiration power on
the minimum acting on the power regulator placed on the suc-
tion unit (ref. 29)
Use of the nozzels:
Oxides from 25 up to 50 My = nozzle 0.8 mm – Small (ref. 22)
Oxides from 50 up to 120 My = nozzle 1.2 mm – Medium (ref. 23)
Oxides from 120 up to 250 My = nozzle 1.5 mm – Large (ref. 24)
Container with WHITE cap for aluminum oxides from 25 up to
120 My.
BLUE cap container for aluminum oxides from 120 up to 250 My.
Loading the containers
1
Unscrew the aluminium stopper of the container for loading
(ref. 1) and pour the prechosen abrasive using the funnel de-
livered with equipme nt.
+49 4152 809680 ·
+49 4152 809696 · www.beco-professionals.com
Delivery
1 power cords
1 neon lamp(9 Watt,
41 Lumen)
3 nozzles
1 funnel loading sands
1 operating instruction
1 warranty
3 /12
Tabla de contenido
loading

Este manual también es adecuado para:

313632

Tabla de contenido