Install Light Bulbs; Connect The Wiring - Broan EVOLUTION QP130 Serie Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

HOUSE
POWER CABLE
12
Run House Power cable between service panel
and hood location. Attach power cable to hood using
appropriate clamp.
13
Hang hood from (5) mounting screws driven part-way
into cabinet locations (shown in illustrations under
"PREPARE HOOD LOCATION"). Mounting screws are
included in parts bag. Slide hood back towards wall until
mounting screw heads are engaged in narrow end of
keyhole slots in top of hood. Tighten screws securely.
14
DuctED inStaLLation onLY:
Connect ductwork to hood and use duct tape to make
joints secure and air-tight. Make sure the damper / duct
connector enters the ductwork and that the damper
opens and closes freely.

connEct tHE wiring

GROUND
SCREW
15
Connect House Power cable to range hood wiring -
BLACK to BLACK, WHITE to WHITE, and GREEN or
BARE WIRE to ground Screw. Replace electrical wiring
box cover.
QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW
HOUSE
POWER
CABLE
models QP130Bl • QP130BlC • QP130ss • QP130ssC

inStaLL LigHt BuLBS

HALOGEN
BULB
CLOCKWISE
LIGHT PANEL
SCREWS
caution: Bulbs may be hot. refer to bulb
packaging for further information.
16
Install (4) Halogen Bulbs. Use 120 V, 35 W, shielded
halogen bulbs - MR16 with GU10 base. Purchase bulbs
separately.
NOTE: Suction cup tool (included with hood) can be
used to install and remove light bulbs.
Align pins on bulb with large diameter opening on socket,
then push bulb in towards hood and rotate clockwise until
firmly seated.
The position of the bulb socket (depth) is adjustable and
may be necessary when:
a) certain brands of bulbs are difficult to install.
b) the bulb protrudes too far below the light panel.
LAMP SOCKET
BRACKET
LIGHT
PANEL
To change the depth of bulb sockets:
- Remove 2 Light Panel Screws. Set screws aside.
- Loosen 2 Screws holding Lamp Socket Bracket to
Light Panel.
- Adjust socket/bracket to desired depth.
- Re-tighten screws securely.
- Re-attach light panel.
DuctED inStaLLation onLY:
17
Re-install aluminum filters removed in Step 5.
non-DuctED inStaLLation onLY:
Install aluminum filters and non-ducted filters - purchased
and assembled in Step 8.
SUCTION
CUP TOOL
(1)
PUSH IN
(2)
ROTATE
SCREWS
Page 5
LIGHT PANEL
Tabla de contenido
loading

Tabla de contenido