Season Cleaning
If the machine will be unused for a long time, please do as following :
• Pull out drainage plug upper / lower to flow out water.
• Let the machine runs under fan mode for 2 hours to dry out the
machine internal.
• Turn off machine and pull out plug.
• Clean and dry filters, then reinstall them.
• Pull out exhaust pipe for safekeeping.
• Put the machine into plastic bag , and place it on a dry place.
Please contact professional serviceman without delay in following situation
Trouble
Machine cannot work
Machine auto restarts
frequently
Too noisy
Compressor cannot work
Note: when abnormal situations are occurred, turn off machine and pull out plug,
then contact with professional electrician for help .
Trouble Shooting
Cause
Power off
"P2" flashes on screen or
water-full indicator turns on
Timer-off turns on
Direct sunlight
Door and windows are open,
many heat sources in the
room
Filters are too dirty
Air-inlet or air out-let is
blocked
Machine is not put on flat
ground
Compressor time-delay
protection turns on
GB-14
Solution
Power on
Drain water out
Turn off machine for three
minutes, then restart it
Draw the curtains
Close the door and windows,
move out heat sources
Clean or replace filters
Remove blockage
Place it on flat and solid
ground, avoiding shaking
Wait for 3 minutes, then
restart the machine after
temperature reduces