Parameters of product range
Specification
Model
Heating Capacity
kW
(Air 26℃, Water 26℃)
C.O.P.
(Air 26℃, Water 26℃)
Heating Capacity *
kW
(Air 15℃, Water 26℃)
C.O.P. *
(Air 15℃, Water 26℃)
Cooling Capacity *
kW
(Air 35℃, Water 28℃)
E.E.R.
(Air 35℃, Water 28℃)
Rated Input Power *
Power supply
Rated current
(A)
Operating air temperature
Advised water flux
m³/h
Water pipe in-out spec mm
NW /GW
Kg
*C.O.P: Coefficient of performance
Note:
1.
78508~78514 can work well under air temp +0
℃
-7
~43℃, performance cannot be guaranteed outside the operating ranges and must take account the
exterior conditions of use identified to select suitable mode (such as location, area of swimming pool,
and numbers of swimmer.)
2.
Above parameters are subjected to adjustment periodically for technical improvement with further notice.
Please refer to nameplate on each machine for accurate information.
78508
78509
7.5
10
6.7
6.6
4.8
6.6
4.52
4.64
4
6
4
4
kW
1.1
1.4
230V/1Ph/50Hz
5.0
6.5
℃
0~43
0~43
3-4
4-6
50
50
40/47
55/63
78510
78511
78512
13.5
17.5
25
7
6.7
6.92
9.9
11.4
16.0
4.78
4.68
4.51
8
10
15
4
3.8
4.2
2.1
2.4
3.5
9.5
11.4
16.0
0~43
0~43
0~43
5-7
6.5-8.5
7-9
50
50
50
70/80
72/82
105/117
℃
~43℃ ; 78739~78740 can work well under air temp
18
78513
78514
78739
25
33
45
6.92
6.8
7
16.0
22.2
29.4
4.60
5.16
5.04
15
20
27
4.2
4
4.5
3.5
4.3
5.8
400V/3Ph/50Hz
5.5
9.2
11.4
0~43
0~43
-7~43
7-9
10-12
15-20
50
50
63
105/117
123/138
215/236
78740
60
6.8
40.1
5.05
36
4.5
7.9
15.2
-7~43
20-25
63
225/246