Troubleshooting - AIR SYSTEMS INTERNATIONAL AC Serie Guia De Inicio Rapido

Ventiladores axiales
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

GE NE R AL SE T UP & OP E R AT ION
1.)
Place fan in a clean air environment.
2.)
Air quality of the confined space should be tested prior to ventilation. If air quality of the
confined space is unacceptable, consult a trained professional.
3.)
Inspect fan for damaged or worn parts. Inspect all ducting and couplings for air leaks prior
to fan operation.
4.)
Install duct cuff to exhaust flange and tighten cinch strap. Keep bends and kinks in ducting
to a minimum to maximize air flow. If canister model is used, open lid and pull out ducting
and inspect for air leaks.
Note: Maximum recommended duct hose length is 25 ft.
5.)
Set fan upwind from the work location and a minimum of 5 ft. from manhole.
6.)
Connect fan to power source.
DC versions require 12 VDC (attach red lead to the positive terminal, black lead to the
negative terminal on battery). This unit must be run in the positive pressure mode as
this model is not approved for extracting (sucking) air. DO NOT REVERSE
WIRING. Warning: Vehicular electrical systems must be able to handle 15
amp service or electrical damage may occur.
AC versions require 120 VAC, 15 amp, 60Hz service.
Note: If an extension cord is required, the minimum recommended size
is 14 AWG (0-25 ft.). For further information, refer to the National Electric
Code Tables, Article 400.
7.)
Push on/off switch to "I" position.
T R OUBL E SHOOT ING
PR OBL E M
Excessive vibration Air intake blocked
Possible internal damage
Possible external damage
Fan will not start
Circuit breaker trips
AC VERSION
Faulty wall outlet
Faulty Capacitor
Fan will not start
Blown Fuse (DC version only) Check and replace. Use only a 20A 32V fuse
DC VERSION
Battery Connection
P OSSIBL E CAUSE
-4-
SOL UT ION
Turn fan off and clear debris from intake
Turn fan off and inspect fan blades, shaft, and housing
for debris, damage, and loose screws.
Note: Never run fan for extended periods without
installing duct on the exhaust flange.
Turn fan off and inspect
Wattage output insufficient
Extension cord improperly sized
Test voltage with meter
Check and replace. Order Part #ELCP75MFD
Ensure proper connection from battery clips to battery
terminal posts