Outdoor side heat exchanger of heat pump: Air
Indoor side heat exchanger of heat pump: Air
Indication if the heater is equipped with a supplementary heater: no
If applicable: driver of compressor: electric motor
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons are
optional.
Item
Symbol
Rated heatling
P
capacity
Declared heating capacity for part load at indoor
temperature 20 ° C
and outdoor temperature T
Item
symbol
Tj = -7℃
Tj = 2℃
Tj = 7℃
Tj = 12℃
T
= bivalent
biv
temperature
T
= operating limit
OL
For air-to-water heat
= – 15 °C
pumps: T
j
< – 20 °C)
(if T
OL
Bivalent
temperature
Degradation
co-efficient heat
pumps (**)
Power consumption in modes other than 'active mode'
Off mode
Thermostat-off
mode
Crankcase heater
mode
Capacity control
Sound power
level,indoor/outdoor
measured
Emissions of
NO
nitrogen oxides (if
applicable)
GWP of the
refrigerant
Address: Corts Catalanes, 7 (1ª planta), 08173-Sant Cugat del Valles (Barcelona) -Spain
Telephone: +34 935 041 292
Contact details
Fax: +34 935 041 293
Information requirements for heat pumps
Indoor unit(s)
Outdoor unit
Value
Unit
11.9
kW
rated,h
j
value
unit
Pdh
kW
10.203
Pdh
kW
6.506
Pdh
kW
4.360
Pdh
kW
4.435
Pdh
kW
10.203
Pdh
kW
8.618
Pdh
kW
x,x
T
°C
-7
biv
C
0.25
dh
P
0.010
kW
off
0.020
kW
P
TO
P
0.000
kW
CK
variable
L
70/71
dB
WA
mg/kWh
(**)
x
fuel
x
input GCV
kg CO
2088
(100 years)
Item
Seasonal space heating
energy efficiency
Declared coefficient of performance or gas utilisation
energy factor for part load at given outdoor temperatures T
Item
Tj = -7℃
Tj = 2℃
Tj = 7℃
Tj = 12℃
T
= bivalent
biv
temperature
T
= operating limit
OL
For air-to-water heat
= – 15 °C
pumps: T
j
< – 20 °C)
(if T
OL
For water-to-air heat
pumps: Operation
limit temperature
Back-up heating
capacity (*)
Type of energy input
Standby mode
Other items
For air-to-air heat pumps:
air flow
rate, outdoor
measured
For water/brine-to-air
heat pumps: Rated
brine or water flow
rate, outdoor side heat
exchanger
2 eq
SNB140FWM
SUB140CAT
Symbol
Value
η
157.0
s,h
efficiency/auxiliary
symbol
value
COPd
267.6
COPd
388.6
COPd
536.4
COPd
633.2
COPd
267.6
COPd
202.0
COPd
T
ol
Supplementary heater
elbu
P
0.010
sb
6800
Unit
%
j
unit
%
%
%
%
%
%
%
x,x
°C
-15
kW
1.9
kW
m3/h
x
m3/h