Wiring Connections; Electrical - Eco-Flo EFLS10 Manual Del Propietário

Ocultar thumbs Ver también para EFLS10:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Disconnect power before working on
pump, motor, pressure switch or wiring
Motor may be hot. Allow to cool 20
!
minutes.
Water pressure may have built up in
!
the pump, pipes and/or tank. Drain
water to relieve pressure.
Motor Voltage Settings
Motors are designed to run on either 115 volt or 230 volt
current. Be sure the motor's current is set to match the
current being supplied to your motor from the electrical
source.
To set your motor to the correct voltage, first remove the
rear cover plate. Next slide the voltage conversion switch
to the correct voltage. WIRING THE PUMP FOR THE
INCORRECT VOLTAGE WILL DAMAGE THE PUMP.
Plate Screws

Wiring Connections

Risk of electric shock. Electricity
can shock, burn or kill.
1. To avoid dangerous or fatal electrical shock, turn OFF
power to motor before working on electrical
connections.
2. Ground motor before connecting to electrical power
supply. Failure to ground motor can cause severe or
fatal electrical shock hazard.
3. Supply voltage must be within +/- 10% of nameplate
voltage. Incorrect voltage can cause fire or damage
motor and voids warranty. If in doubt consult a
licensed electrician.
Wiring Chart Recommended Wire and Fuse Sizes for 115 and 230 volts
FULL LOAD
MOTOR HP VOLTS
AMPS
1
115/230
16.32/8.16
1-1/2
115/230
20.09/10.05
2
115/230
20.75/10.38
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561

ELECTRICAL

Motor Cover Plate
BRANCH FUSE
BREAKER
AWG MIN. WIRE
RATING AMP
SIZE (mm
)
2
30/15
10/14 (5.5/2)
30/15
10/14 (5.5/2)
30/20
8/12 (8.9/3)
115
SET FOR 115V
230
SET FOR 230V
4. Use wire size specified in Wiring Chart (below). If
possible, connect pump to a separate branch circuit
with no other appliances on it.
5. Do not ground to a gas supply line.
6. Wire motor according to diagram on motor nameplate.
If nameplate diagram differs from diagrams above,
follow nameplate diagram.
7. If this procedure or the wiring diagrams are
confusing, consult a licensed electrician.
NOTICE
Pump must be on dedicated circuit
not shared by any other equipment
DISTANCE IN FEET FROM MOTOR TO SUPPLY
0-100
101-200
AWG WIRE SIZE (mm
10/14 (5.5/2)
8/14 (2/2)
10/14 (5.5/2)
8/14 (8.4/2)
8/12 (8.9/3)
8/12 (8.4/3)
6/10 (14/5.5) 4/10 (21/5.5)
6
HOT
L1
TO BREAKER
L2
NEUTRAL
TO BREAKER
HOT
L1
TO BREAKER
L2
HOT
TO BREAKER
.
201-300
301-400
)
2
6/14 (14/2)
6/12 (14/3)
4/10 (21/5.5)
6/12 (14/3)
4/10 (21/5.5)
4/10 (21/5.5)
4/10 (21/5.5)
401-500
Tabla de contenido
loading

Este manual también es adecuado para:

Efls15Efls20

Tabla de contenido