Operation & Programming - Sioux Tools TAA1000 Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8
1. Charger input
4. Analog out
5. ENTER (ON) key
1.
Plug in the supplied charger here. LED will glow RED during charge and GREEN when complete.
2.
SIX (6) pin Bendix style connector for transducer input.
3.
OK/PEAK/NOK LED indicators. OK/NOK will light according to the torque being within limits; PEAK lights when the socket stops
rotating.
4.
BNC Analog output style connector to access real time torque with an oscilloscope for joint and tool analysis.
5.
ENTER key is used to accept a selected option and is also the "ON" button to turn the TAA1000 on for operation. "OFF" is
automatic after 5 minutes of non-activity.
6.
The RETURN key will allow the operator to go back to the prior selection. Holding the key down for 2 seconds will allow clearing
of the memory and STATISTICS readings stored.
7.
RS232 (DB9) used for printer and laptop connection for data download under ASCII format.
To switch "ON" the TAA1000, press the
LED test, the "CAL TRANSDUCER?" box will appear. Answer the question and follow the menu driven set-up according to the
following menu tree:
CAL. TRANSDUCER
UP/YES
—-SET UNITS—-
UNITS: NM
-CAL. TRANSDUCER-
TQ: 0075 NM
UP/ NON CONTACT
DWN/ INDUSTRY STD
T: 0.0 NM
H: 50.0
RUN SCREEN
HIGH Torque Limit
1.
Use the UP / DWN arrow keys to adjust values. Holding it down will cause fast scrolling while individual taps will increment the
value slowly.
2.
Press the RETURN key to get back to the RUN Screen.
3.
Press and hold the RETURN key to clear the memory.
Layout & Operator Interface
Operation & Programming
ENTER button momentarily. After the initial software version identifier screen and
DOWN/NO
Last torque reading
# of Memory readings
08
L: 40.0
LOW Torque Limit
General Notes
3. Indicator LED's
2. Transducer Input
7. Printer (RS232) output
6. RETURN key
From the RUN SCREEN use the ENTER key to
access the main MENU. MENU items are:
· LIMITS .................... ENTER to program HI/LOW limits
· BATTERY XX % ..... Indicates battery charge level
· FILTER ................... ENTER to choose PULSE or
· CALIBRATE ........... ENTER to start CAL routine
· RS 232 (19200) ...... ENTER to send data to serial port
· STATS .................... ENTER to view STATS; UP/DWN
2
GEAR
Tabla de contenido
loading

Tabla de contenido