ENGLISH
HEAT EXCHANGER, CONDENSE TRAY REMOVAL AND SERVICING
Disconnect the flexible pipe from the condense adapter, be aware the condense pipe may contain water.
Withdraw the heat exchanger and condense tray assembly by pulling on the securing strap and remove from the unit. Take
care to avoid damaging the heat exchanger air passages. See Figure 18 & 19.
Be aware, the condensate tray may contain water.
Check all the air passages in the heat exchanger are free from obstruction. If not clean by acuuming or with a light brush.
NOTE: DO NOT USE WATER OR ANY OTHER FLUIDS.
NOTE: Under no circumstance must any sharp implements which are likely to distort or puncture the heat exchanger air
passage walls, be used.
Wipe clean the condensate tray.
17
SERVICING CARRIED OUT WITH FANS IN PLACE (recommended)
Remove all dust etc. from both the impellor and the motor, taking care not to disturb the balance of the fan.
Refit or replacement is in reverse order.
FAN CASE ASSEMBLY REMOVAL & SERVICING
Referring to section 13.3 to 13.7 remove the heat exchanger and condense tray assembly. Remember there may be water
in the condensate tray.
Disconnect the PCB board and fan cables from the terminal.
Push the twin fan case assembly towards the void and down
to remove.
Clean fans through the holes in the casing where necessary, use a soft
brush or vacuum.
18
19
FAN
ASSEMBLY
Figure 19. Mains cover plate & fan assembly
18
MAINS SUPPLY
COVER PLATE
HEAT
EXCHANGER
AIR PASSAGES
19
20
Figure 20 Slide back and down to remove
Figure 18. Removing
heat
exchanger
&
condensate tray
TERMINAL
63