INSTALLATION & ASSEMBLY:
1.
Remove fixture from box.
2.
Open the door frame (#1) by rotating the two
cam latches (#2) [Fig. 1].
3.
Remove the lamps (#3) from the packaging
material and put them in a safe place [Fig. 1].
4.
Remove the wire cover (#4) by squeezing and
releasing it from locking tabs (#5) [Fig. 1].
5.
Close the door frame (#1) and place the fixture
on a 2 ft by 4 ft T-bar grid in the desired location
[Fig. 2].
6.
From above the ceiling, secure troffer to T-Bar
by bending built in T-bar clips (#6) on all four
corners of fixture [Fig. 3].
7.
If local code requires, tie a wire to at least two of
the four T-bar clips (#6) to a structural member
of the ceiling.
8.
Remove the access plate (#7) and locate
fixture supply wires (1 black & 1 white) [Fig. 3
& 4].
9.
Remove one knockout (#8) in access plate (#7)
and pull fixture supply wires through knockout
(#8) opening [Fig. 4 & 5].
10. Make electrical connections according to local
code.
11. From below ceiling, open the door frame (#1)
and replace the wire cover (#4) by squeezing it
into the locking tabs (#5) [Fig. 1].
12. Install lamp (#3) with side labeled "power" on the
lamp holders closest to the access plate (#7).
13. Close the door frame (#1) using the two cam
latches (#2) [Fig. 1].
14. Turn power on.