Section 2. Operating Instructions; To Operate The Light; Section 3. Replacing The Lamp; Figure 1. Removing The Pool And Spa White Light Assembly For Lamp Replacement - Zodiac Jandy Operacion

Luces blancas subacuáticas para piscinas y spas
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Section 2. Operating Instructions

2.1

to Operate the light

Activate the light by either turning on the switch, setting
a program, or by pushing the button on a pool and spa
controller.

Section 3. Replacing the lamp

WARNING
Always disconnect power to the pool or spa white
light at the circuit breaker before servicing the light.
Failure to do so could result in death or serious injury
to installer, serviceman, pool or spa users or others
due to electrical shock.
1.
Turn off the main electrical switch or circuit
breaker, as well as the switch, which operates the
underwater light.
Jandy Model
pool/Spa White light
12 Volt AC
pool White light
120 Volt AC
pool White light
12 Volt AC
pool White light
120 Volt AC
Spa White light
120 Volt AC
table 1.
lamp Specifications
POOL WHITE LIGHT
ASSEMBLY
Power
Niche
Cord
Bonding
cable
POSITIONING TAB
TAB LOCATOR

Figure 1. Removing the pool and Spa White light Assembly for lamp Replacement

Jandy
Underwater Pool and Spa White Lights
®
Fixture
Lamp
Voltage
Voltage
Wattage
12V
100 Watt
120V
300 Watt
12V
300 Watt
120V
500 Watt
120V
POOL WALL
Unscrew pilot screw
1
and pull top of light
assembly away from
pool wall
PILOT SCREW
2
|
Operation Manual
2.
Be sure to have the following items:
• A new lens gasket (P/N R0451101 for Jandy
Pool Light and P/N R0400501 for Jandy Spa
Light).
• One (1) new lamp. See Table 1 for
specifications.
Replace the lamp with one of the same type and
wattage. Failure to replace the lamp with one of
the same type will damage the light assembly and
may cause an electrical hazard resulting in death
or serious injury to pool or spa users, installers, or
others due to electrical shock, and may also cause
damage to property. Be sure the power is switched
OFF before removing or installing lamps. Allow lamp
to cool before replacing.
3.
To remove the light assembly, unscrew the special
pilot screw at the top of the face ring, remove light
assembly from niche and gently place assembly on
the deck. It is not necessary to drain down the pool
or spa. See Figure 1.
Lamp
Lamp Type
R20 Flood
R40 Flood
R40 Flood
R40 Flood
60 Watt
R20 Flood
Power
Cord
Bonding
cable
Push up on
bottom of
light assembly
POSITIONING TAB
ENGLISH
WARNING
Qty. per
Lamp Kit
Fixture
Part Number
1
R0450501
1
R0450502
1
R0450503
1
R0450504
1
R0450505
SPA WHITE LIGHT
ASSEMBLY
SPA WALL
Niche
1
TAB LOCATOR
Page 5
Unscrew pilot screw
and pull top of light
assembly away from
spa wall
PILOT SCREW
2
Push up on
bottom of
light assembly