2. Cleaning the filter
1. Take out the filter in the right.
2. Take out the carbon filter
3. Clean it with a vacuum or water each two weeks.
4. Never clean the filter of carbon with water
If your device has any problem prove the next points:
PROBLEM
Problem
RESOLUTION
The ventilator or
compressor don't
work
The ventilator
works but not the
compressor.
It doesn't
dehumidificate
Extrange noises
The evaporator
gets frozen
Water falls
Atención: si el cable de alimentación está estropeado, debe ser reemplazado por personal técnico
especializado. Contacte con el servicio técnico autorizado o vendedor.
Posible cause
Voltage problems
Plug damaged
Harmed motor
Voltage problems
Plug damaged
Harmed compressor
The defrost mode is on
Dirty filter
Gas
Humidity temperature too high
Desnivelated floor
Motor or compressor
Water
Dirty filter
Defrost system
Deposit
Dehumidifier
Probable solution probable
Proove voltage
Contact with an electrician
Contact with the autorized
service
Contact with an electrician
Wait 3 minutes
Contact with the technical
service
Is normal
Clean the filter
Contact with the technical
service
Is normal
Put the device the most regular
you can
Contact with the technical
service
It is normal
Clean it
Disconect it and talk with the
technical service
Contact with the seller
ENG
7