First Power On - Teleco TVPLA868CC2EN Manual Del Usuario

Dispositivo de mando 24vdc con radio receptor para controlar uno o dos motores 24vdc con encoder para lamas regulables
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

1
CONNECTIONS, ADJUSTMENTS AND CONTROL UNIT WARNINGS
13
Aerial
12
11
P1
P2
RAIN
10
not
sensor
9
used
WIND
8
sensor
7
Optional LED CARD
(only in TVPLAxxxCC2EN version)
LED COLOUR
STATUS
ON until next manoeuvre
L1
RED
Flashing during movement
ON until next manoeuvre
L2
RED
Flashing during movement
L3
BLUE
ON
One flash every second
One flash every 2 s
L4
RED
One flash every 10 s
Two quick flashes every 10 s
Three quick flashes every 10 s
Four quick flashes every 10 s
Five quick flashes
Six quick flashes
Seven quick flashes
Eight quick flashes
Nine quick flashes
Ten quick flashes
Twelve quick flashes
One flash every 2 s
One flash every 3 s
L5
ON
RED
16 17 18 19
DIP switch
Encoder M2
Encoder M1
TEMP.
14
20 21 22 23
15
Sensor
L2
ATTENTION! The electronic
L1
board is protected by a 10A
fuse. The maximum allowed
Memory
power, including the plug-in
LED controller board, is 240W.
L3
L4
MEANING
MOTOR 1: Limit switch or alarm
MOTOR 1 moving with encoder communication
MOTOR 2: Limit switch or alarm
MOTOR 2 moving with encoder communication
Synchronized mode activated
Synchronized mode activated (during configuration)
Independent mode activated (during configuration)
Water draining alarm (par. 4.4, page 12)
Rain alarm (par. 4.4, page 12)
Ice / Snow alarm (par. 4.2 - 4.3, pages 11-12)
Wind alarm (par. 4.1, page 11)
Unexpected absorption of one motor in synchronized mode
Built-in motor limit switch activated
Motor stopped by current absorption over the threshold
Safety limit switch
Encoder signal error. The motor stops.
One motor is short-circuited
Encoder signal disturbed. Abnormal motor operation.
Rain sensor is deactivated
Temperature sensor is deactivated
Power ON
L5
6
5
4
3
-
2
+
1
10A Fuse
3
1
+24V
2
POWER SUPPLY GND
3
MOTOR 1 (OPEN)
M2
4
MOTOR 1 (CLOSE)
5
MOTOR 2 (OPEN)
6
MOTOR 2 (CLOSE)
M1
7
WIND SENSOR (BROWN)
8
WIND SENSOR (BLUE)
9
RAIN SENSOR (WHITE, +12V
24V
10
RAIN SENSOR (BLUE, SIGNAL)
Power supply
11
RAIN SENSOR (YELLOW, GND)
12
AERIAL RF
13
AERIAL GND
14
TEMPERATURE SENSOR (BLACK)
15
TEMPERATURE SENSOR (WHITE)
16
ENCODER M2 (VDD)
17
ENCODER M2 (Signal A)
18
ENCODER M2 (Signal B)
19
ENCODER M2 (GND)
20
ENCODER M1 (GND)
21
ENCODER M1 (Signal B)
22
ENCODER M1 (Signal A)
23
ENCODER M1 (VDD)
DIP
MEANING
1 - 2 - 3
Setting of wind sensor threshold (see par. 4.1, page 11)
4 - 5
Motor control mode (see pages 4...7)
Maximum motor current threshold set during configuration
6
(see par. 2.4, page 7)
= It takes effect DURING configuration
FIRST POWER ON: at first power-on, the system is waiting
to be programmed with the memorization of at least one
transmitter (par. 3, page 8) and the configuration of the
motors and relative working time (see next pages).
= Weather sensor alarms (from LOW to HIGH priority)
= MOTOR alarms
POWER SUPPLY
)
Tabla de contenido
loading

Este manual también es adecuado para:

Tvpla868cc2enbTvpla916cc2enTvpla916cc2enb

Tabla de contenido