AVS Electronics OUTSPIDER PA Manual De Instrucciones página 48

Ocultar thumbs Ver también para OUTSPIDER PA:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Sensors management
Access to this menu require a choice in type of connection:
1- Follow the procedure based on the the type of connection to be carried out
NOTE: if it is a USB connection, it may require installation of drivers for recognising the peripheral device. If the drivers are not recognised automatically, it
is necessary to specify the following file path to the operating system C:\Programmi\Xwin\Driver\ and select the stmcdcAVS.inf file
2- Select the address of the sensor and/or the satellite on HPWIN and then chose "Connetti (Connect)"
NOTE: once connected the sensor model and firmware version will be displayed.
Besides this, information related to the sensor will be displayed in real time, from the field
signal to the status of the outputs; is will also be possible to make operational parameter
changes and synchronise date and time with the PC.
E
Adjust date and time
This setting is important for handling sensor events history.
N
G
Œ
Display parameters
These parameters highlight:
Status of Outputs
This section indicates the state of the receiver, the corresponding led goes from green to red when:
Temperature: indicates sensor operational temperature.
Comp: indicates the type of connection (BUS or RELAY) and therefore the position of DIP1 in SW2
Power supply: indicates the power present on the sensor
Alarm: if the sensor is in alarm status
Tamper: if the sensor has been tampered
Aux: if the auxiliary input of the sensor is enabled and open
Antimask: if the sensor is in anti-masking alarm status
Lenses: if the sensor detect the dirty lenses condition
Microwave:
Œ
Select "Allinea ora (Align hour)"
Confirm by pressing "Yes" to synchronise date and time with that of the PC
if the microwave section is in alarm status (Mod. OutSpider DT and Outspider DT WS(UB)(U))
- 48 -
Tabla de contenido
loading

Tabla de contenido