Troubleshooting - Neumann.Berlin TLM 103 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8

7. Troubleshooting

Problem
Possible causes
Microphone
The phantom power supply voltage is not
not operating
switched on at the mixing console or at the
power supply equipment.
The power supply equipment is not con-
nected to the power supply line or there is
no battery.
No signal
The microphone is not connected to the
transmission
correct microphone amplifier input of the
subsequent equipment.
8. Technical data and
connector assignments
Permissible atmospheric conditions:
1)
Operating temperature range ........... 0 °C ... +70 °C
Storage temperature range ...........−0 °C ... +70 °C
Humidity range ..................... 0 % ... 90 % at +0 °C
0 % ... 85 % at +60 °C
Acoustical op. principle .............Pressure gradient
Directional pattern .................................... Cardioid
Frequency range ...............................0 Hz...0 kHz
Sensitivity
)
................ mV/Pa = –.5 dBV ± 1 dB
Rated impedance ........................................50 ohms
Rated load impedance ..........................1000 ohms
Signal-to-noise ratio
,
)
CCIR
4)
............................................................ 76.5 dB
Signal-to-noise ratio
)
,
A-weighted
.................................................... 87 dB
4)
Equivalent noise level,
CCIR
............................................................. 17.5 dB
4)
Equivalent noise level,
A-weighted
4)
................................................... 7 dB-A
Max. SPL for
5)
less than 0.5 % THD ..................................... 18 dB
Max. output voltage .......................................1 dBu
Supply voltage
6)
....................................... 48 V ± 4 V
Current consumption
6)
....................................  mA
Matching connector .......................................XLRF
Weight ............................................................. 500 g
Dimensions ............................... Ø 60 mm x 1 mm
94 dB SPL equiv. to 1 Pa = 10 µbar
0 dB equiv. to 0 µPa
EN
4
Solution
Check the corresponding channel settings.
Check the connection to the power supply
line or check the battery of the power supply
equipment.
Check the signal path.
If necessary, activate the appropriate input
on the corresponding channel of the mixing
console.
The microphone has a balanced, transformerless
output. The -pin XLR connector has the following
standard pin assignments:
Pin 1:
0 V/Ground
Pin :
Modulation (+phase)
Pin :
Modulation (–phase)
transducer
All values for non-condensing humidity. The values are
1)
valid for clean and well-looked-after microphones or
microphone capsules, respectively. Any kind of pollution
of capsules and membranes may restrict the said values.
at 1 kHz into 1 kohms rated load impedance.
)
)
re 94 dB SPL
according to IEC 6068-1;
4)
CCIR-weighting acccording to CCIR 468-, quasi peak;
A-weighting according to IEC 6167-1, RMS
5)
THD of microphone amplifier at an input voltage equiva-
lent to the capsule output at the specified SPL.
6)
Phantom powering (P 48, IEC 198).
9. Selected Accessories*
(see photos in appendix)
Elastic Suspension
EA 1 ..........................ni .................Cat. No. 008449
Auditorium Hanger
MNV 87 ....................ni .................Cat. No. 006804
Mount
DS 10 .....................blk ...............Cat. No. 0074
SG 1 ..........................blk ...............Cat. No. 008445
Popscreen
PS 15 ........................blk ...............Cat. No. 00847
PS 0 a ....................blk ...............Cat. No. 008488
Windscreen
WS 87 ......................blk ...............Cat. No. 00675
Battery Supply
BS 48 i .....................blk ...............Cat. No. 006494
BS 48 i- ..................blk ...............Cat. No. 006496
Power Supply
N 48 EU .................blk ...............Cat. No. 00857
N 48 US .................blk ...............Cat. No. 00858
N 48 UK .................blk ...............Cat. No. 00859
Connecting Cable
IC  mt (10 m) ..........blk ...............Cat. No. 00654
IC 4 (10 m) ...............ni .................Cat. No. 006547
IC 1 mt (5 m) ..........blk ...............Cat. No. 006570
Adapter Cable
AC  (0. m) ................................Cat. No. 006598
AC 5 (0. m) ................................Cat. No. 006600
AC 7 (0. m) ................................Cat. No. 00660
Meaning of color codes:
ni = nickel, blk = black
* Detailed descriptions and additional articles can be found
in our accessories catalog or at: www.neumann.com