Distance & Spot Size
As the distance (D) from the object increases, the spot size (S) of the area
measured becomes larger. The meter's D:S ratio is 8:1, so at 8 inches (203mm),
the diameter of the target being measured must be at least 1" (25.4mm).
inch
mm
Distance (D): Spot (S) = 8:1
(Typically, the spot size indicates 90% encircled energy)
Operation
1. Hold the meter by the handle grip and point the meter towards the object
being measured.
2. Pull and hold the trigger to turn the meter on. While measuring,
the SCAN icon will appear on the display. Read the temperature reading
on the display. If the display does not turn on, replace the battery.
3. Release the trigger and the HOLD display icon will appear on the LCD
indicating that the reading is being held.
a. In the HOLD mode, press the "
control the laser and backlight:
Press once:
Laser on
Press twice:
Backlight on
Press three times:
Laser off
Press four times:
Backlight off
b. Press the °C /°F button to select temperature units.
4. The meter will automatically power down after approximately 8 seconds
after the trigger is released.
Sensor Beam
" button in the following sequence to
Backlight off
Laser on
Backlight on
Laser off
3
Operation cont.
5. While the trigger is pulled, the meter will record the highest and lowest
temperature measurements. Press the MAX/MIN button to recall the
highest (MAX) and lowest (MIN) temperature readings.
NOTE:
• Make sure that the target is larger than the spot size displayed by the
Distance: Spot diagram printed on the side of the meter.
• If the surface area is highly reflective, apply electrical tape or flat black
paint to surface before measuring. Allow time for tape or paint to adjust
to temperature.
• The meter cannot measure through transparent surfaces such as glass.
It will measure the surface temperature of the glass instead.
• Steam, dust, smoke, etc., can block measurements.
• Make sure the surface being measured is free of frost, dirt, oil, etc.
• The meter automatically corrects for changes in ambient temperature.
However, it can take up to 30 minutes to adjust to wide variations.

Battery Replacement

1. The LCD will display a " " low battery symbol
when it's time to replace the battery.
2. Note the two depressions on
either side of the meter near
the trigger.
Pull down from this spot to open
the battery cover.
Remove and safely discard the
old battery.
Replace with a new 9-Volt battery
and close the battery cover.
Low Battery
Indicator
9-Volt
Battery Cover: