Grohe 36 206 Manual De Usuario página 11

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
Functions for urinal/WC fittings
Trigger flushing
Function
Button
ON
Trigger flushing
AUTO
Switch on/off intermediate flush
Factory setting: Switched on
Function
Button
TEST
Initiation
OFF
Switch on/off
AUTO
TEST
Finish
or after 60 s
This function is available for products with a manufacturing
date later than 01.08.2003. On older fittings, the fitting is
switched off when the relevant buttons are pressed.
Switch automatic flushing on/off
Factory setting: Switched on
Automatic flushing serves to ensure water hygiene in the event
of long-term non-utilisation of the fitting.
Flush interval after non-use for urinal fittings = 24 hours, for
WC fittings = 72 hours
Function
Button
RESET
Switch on
Hold and
within 3 s:
OFF
AUTO
RESET
Switch off
Hold and
within 3 s:
OFF
AUTO
Indicator lamp
Water runs for preset time
Indicator lamp
Switched on:
Switched off:
Switch by pressing button
again
Indicator lamp
Switch pre-flush on/off
Factory setting: Switched off
Function
Button
TEST
Initiation
ON
Switch on/off
AUTO
TEST
End setting
or after 60 s
This function is available for battery-operated products with
a manufacturing date after 01.07.2007.
Set minimum delay time
Battery fitting factory setting: 5 s
Mains fitting factory setting: 7 s
Function
Button
TEST
Initiation
Increase
minimum delay
time
Reduce
minimum delay
time
TEST
Finish
or after 60 s
This function is available for battery-operated products with
a manufacturing date after 01.07.2007.
Indicator lamp
Switched on:
Switched off:
Switch by pressing button
again
Indicator lamp
Per stage (1 s):
End position (10 s):
Per stage (1 s):
End position (10 s):
8
Tabla de contenido
loading

Tabla de contenido