Technical Data; Noise And Vibration; Eu Declaration Of Conformity; Statement Of Use - Chicago Pneumatic CP7215 SERIES Manual Del Operador

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
Random orbital Sanders

Technical data

Free speed (rpm)
CP7215
12000
CP7215E
12000
CP7215CV
12000
CP7215CVE
12000
CP7215SV
12000
CP7215SVE
12000
CP7225
12000
CP7225E
12000
CP7225CV
12000
CP7225CVE
12000
CP7225SV
12000
CP7225SVE
12000
CP7255
12000
CP7255E
12000
CP7255CV
12000
CP7255CVE
12000
CP7255SV
12000
CP7255SVE
12000

Noise and vibration

Sound pres-
sure level
(dB(A))
CP7215
81
CP7215E
81
CP7215CV
81
CP7215CVE
81
CP7215SV
81
CP7215SVE
81
CP7225
81
CP7225E
81
CP7225CV
81
CP7225CVE
81
CP7225SV
81
CP7225SVE
81
CP7255
81
CP7255E
81
CP7255CV
81
CP7255CVE
81
CP7255SV
81
CP7255SVE
81
Uncertainty 3 dB(A), in accordance with EN ISO 15744. For
Sound power level, add 11 dB(A)
Vibration standard : ISO-28927-3
Weight
Weight
(kg)
(lb)
0.79
1.74
0.79
1.74
0.83
1.83
0.83
1.83
0.82
1.84
0.82
1.84
0.79
1.74
0.79
1.74
0.83
1.83
0.83
1.83
0.82
1.84
0.82
1.84
0.79
1.74
0.79
1.74
0.83
1.83
0.83
1.83
0.82
1.84
0.82
1.84
Vibra-
Vibration
tion (m/s²)
uncertainty
8.54
2.85
5.65
1.83
8.54
2.85
5.65
1.83
8.54
2.85
5.65
1.83
7.65
3.18
3.7
2.08
7.65
3.18
3.7
2.08
7.65
3.18
3.7
2.08
8.22
2.26
5.13
1.79
8.22
2.26
5.13
1.79
8.22
2.26
5.13
1.79
© Chicago Pneumatic - 8940163475
These declared values were obtained by laboratory type test-
ing in accordance with the stated standards and are suitable
for comparison with the declared values of other tools tested
in accordance with the same standards. These declared val-
ues are not adequate for use in risk assessments and values
measured in individual work places may be higher. The ac-
tual exposure values and risk of harm experienced by an indi-
vidual user are unique and depend upon the way the user
works, the workpiece and the workstation design, as well
upon the exposure time and the physical condition of the
user.
We, CHICAGO PNEUMATIC Tool Co. LLC, cannot be
held liable for the consequences of using the declared values,
instead of values reflecting the actual exposure, in an individ-
ual risk assessment in a work place situation over which we
have no control.
This tool may cause hand-arm vibration syndrome if its use
is not adequately managed. An EU guide to managing hand-
arm vibration can be found by accessing
www.pneurop.eu/index.php
lation'.
We recommend a programme of health surveillance to detect
early symptoms which may relate to noise or vibration expo-
sure, so that management procedures can be modified to help
prevent future impairment.
If this equipment is intended for fixtured applications:
The noise emission is given as a guide to the machine-
builder. Noise and vibration emission data for the com-
plete machine should be given in the instruction manual
for the machine.
Declarations

EU DECLARATION OF CONFORMITY

We, CHICAGO PNEUMATIC Tool Co. LLC, 1815 Club-
house Road, Rock Hill, SC 29730, declare under our sole re-
sponsibility that the product (with name, type and serial
number, see front page) is in conformity with the following
Directive(s):
2006/42/EC (17/05/2006)
Harmonized standards applied:
EN ISO 11148-8 : 2012
Authorities can request relevant technical information from:
Pascal Roussy, R&D Manager, Ets Georges Renault, 38 rue
Bobby Sands, BP10273 44818 Saint Herblain, France
Saint-Herblain,
Pascal ROUSSY
Signature of issuer

Statement of use

This product is designed for removing or polishing material
using coated abrasives or polishing attachments. No other
use permitted. For professional use only.
http://
and selecting 'Tools' then 'Legis-
5
Tabla de contenido