- Every time the pre-filter is opened, clean the seal and its housing of any impurities to ensure
airtightness when the cap is closed (Fig. 5).
- Pump components that, due to their normal use, suffer wear and/or tear must be regularly re-
placed to ensure good pump performance. The following table lists the fungible and / or consu-
mable components of the pump and the period of time in which they must have been replaced.
DESCRIPTION OF THE COMPONENT
Capacitor
Bearings
Mechanical seal
O-rings and other sealing components
The opening and closing of the pump for the replacement of any of the inner spare parts does not
(1)
guarantee the subsequent sealing. For this reason, it is recommended that the O-rings and sealing
components are replaced whenever the mechanical seal and / or bearings are changed.
The estimated working life of the above parts has been established according to normal product use and
installation conditions.
Follow the instructions in the installation manual to maintain the working life of the pump.
6. REMOVAL
- The motor unit can be removed from the pump body without having to disconnect the
pump's suction and return pipes.
- To remove the motor unit from the pump body, remove the screws that join them
together.
12
TIME BETWEEN REPLACEMENTS
(1)
Installation and general maintenance manual
1 year
1 year
1 year
1 year
- POOL PUMPS