Safety Notes; Symbol Description; Installation Instructions; Technical Data - Hansgrohe iControl S 15955000 Modo De Empleo / Instrucciones De Montoje

Ocultar thumbs Ver también para iControl S 15955000:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
6

Safety Notes

6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6 The hot and cold supplies must be of equal
pressures.

Installation Instructions

• The fitting must be installed, flushed and tested after
the valid norms.
• Prior to installation, inspect the product for transport
damages.
After it has been installed, no transport or surface
damage will be honoured.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Hansgrohe mixers can be used together with hydrauli-
cally and thermically controlled continuous flow heaters
if the flow pressure is at least 0,15 MPa.
The product is exclusively designed for drinking water!
4
English

Symbol description

max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
Assembly see page 31
Do not use silicone containing acetic acid!
Dimensions (see page 34)
Flow diagram (see page 35)
Spare parts (see page 38)
XXX = Colors
000 = chrome plated
400 = white/chrome plated
Special accessories
flushing unit complete (15956000) order as
an extra
Operation (see page 36)
Cleaning
see enclosed brochure.
Tabla de contenido
loading

Este manual también es adecuado para:

Icontrol e 15958000Puravida 15777 serieMetris 31958000

Tabla de contenido