Trouble Shooting Guide
If this fi xture fails to operate properly, use the guide below
to diagnose and correct the problem.
•
Verify that power is turned on at switch and breaker
Verify that fi xture is wired properly
•
•
Verify that line voltage is correct (120V)
The photocontrol in the "PE" models is designed to turn on
the fi xture light at low light levels (Dusk to Dawn) and has a
rotatable cover to allow adjustment of light entry.
Test if Photocontrol works properly:
If light does not come on or stays on:
•
Close Photocontrol cover - Light should come on.
•
Open Photocontrol cover and shine a fl ashlight into
Photocontrol - Light should go off
If fi xture cycles on and off:
Light refl ecting back off any surrounding surfaces, or from other
light sources enters the photocontol. To correct problem, eliminate
refl ective surfaces, turn the Photocontrol cover to reduce the
opening or reposition the fi xture.
If Photocontrol cover is in closed position, it will allow continuous
operation of fi xture during daylight.
If further technical assistance is required, contact: Technical
Support at: (800) 748-5070
This LED light provides low maintenance service with no bulbs
to change. Clean surfaces with mild soap and water. Do not use
abrasive materials such as scouring pads or powders, steel wool
or abrasive paper.
WARNING: There are no user serviceable parts inside fi xture.