BATTERY CHARGER CABAT-30 (optional)
A system with CT-24M can even function in a power blackout, just install two batteries (12V. 1.3Ah. MAX – not
supplied) and a CABAT-30 battery charger. This does not modify the system in any way.
In new systems, after installation and testing, insert the snap-in battery charger module into the connector but be
very careful to insert the right polarity of the two faston connection cables.
Connection sequence:
- Unplug the 230 Vac power supply.
- Snap in the CABAT30 module.
- Connect the two batteries in series using the cables provided and paying close attention to the polarity.
- Check that the safety lights go on.
- Plug in the network once more.
- The new batteries will be fully charged after approx. 10 hours.
- The number of gate movements possible when powered by battery depends on many factors;
an approximate example could be 4 complete cycles under the following conditions:
- gate 150kg length 3m
- installation with 1 pair of photocells, plug-in receiver and 1 flashing light (20W max.)
- fully charged batteries
- within 5h from 230V power failure
RADIO (optional)
La RADIO must be inserted in connector M (Fig.1).
Canale 1°: Step by step;
Canale 2°: Pedestrian
35