4
Technical data
EN
4.1
Electrical data
Input levels
Maximum recommended PV generator power
MPP range DC from (MPP tracker active) @Pnom
Min. voltage max. voltage in operation
Nominal voltage / Starting voltage
No-load voltage / absolute max. input voltage (Vmax PV)
Max. input current (Inom PV)
Number of strings per MPPT / number of DC inputs per DC con-
troller
Number of MPP controls / number of DC input controls
Max. short-circuit current [ISC PV (max)]
Max. input source feedback current
Polarity safeguard
String fuses
DC overvoltage protection
Output levels
Nominal output @ nominal voltage in volts
Nominal voltage
Voltage range: continuous operation
Nominal current
Max. continuous current
Contribution to peak short-circuit current (îp)
Initial short-circuit alternating current (lk" first single-period ef-
fective value)
Short-circuit alternating current duration
Start-up current
Nominal frequency / Frequency range
Reactive power
cos phi range
Number of feed-in phases
Distortion factor (THD)
Max. voltage range (up to 100 s)
AC overvoltage protection
General electrical data
Max. efficiency
European efficiency
Self consumption: Standby device / accessories
Infeed from
Transformer
Protection class / overvoltage category
Grid monitoring
Page 10
Device variants [See section 4.4} Page 11]
1500 V
160 A
1-2
1
300A
0A
no
no
Yes
Device variants [See section 4.4} Page 11]
3 x 132.3 A
193 A
137 A
134 A
5 A [RMS (20ms)]
50/60 Hz / 45 - 65 Hz
0-100 % Snom
1 - 0.3 ind/cap
3
3 %
825 V
Base
99.2 %
99.1 %
< 10 W
> 200 W
no
I / 3
Country-specific
KACO blueplanet 87.0 TL3 KACO blueplanet 92.0 TL3 KACO blueplanet 110 TL3 KACO blueplanet 125 TL3
KACO blueplanet 137 TL3 KACO blueplanaet 150 TL3