Garage Door Opener 60 / 100
English
Operating Controls (Fig. 01)
01 - (P button) Programming
02 - (A button) Increase
03 - (D button) Decrease
04 - (C button) Programming Transmitters
05 - LED display
Circuit Board Connectors (Fig. 02)
06 - Connector for backup battery
07 - Connector for motor
08 - Connector for power transformer
09 - Terminal to connect the run lamp
10 - Terminal connector for Logic Board
11 - Terminal for connection of photocells or push button (External accessories)
Installation Instructions
Sectional overhead door (max height 2300mm)
01 - Read the instructions carefully;
02 - Make sure the door structure is solid and suitable to be motor driven;
03 - Make sure that when the door is moving there are no friction points;
04 - The door must be balanced;
05 - Install a 230V, adequately protected with ground socket near where the opener is going to be
installed.
Fig. 03
1 - Opener;
2 - START wall switch;
3 - Key selector switch or digital keypad;
4 - Photocells;
5 - 24V 5W max lamp.
Installation Instructions
Use both motor brackets (E) (Fig. 04) to fix the rail to the motor. Fix these brackets to the motor (E) (Fig.
04) with 6mm screw nuts (D) (Fig. 04). Fix the bracket (F) (Fig. 04) where the rail needs to be fixed to the
ceiling.
Installation Instructions
Remember there are specific standards that have to be strictly followed regarding the safety of automatic
gates and doors' electrical installations.
As well as the legal requirements and standards that must be adhered to, please take note of the
following points to ensure maximum safety and reliability of your installation:
01 - Prior to installing check the surrounding environment. Carefully evaluate any hazards there could be
from physical damage (transiting vehicles, parts of trees falling, etc.), possible contact with strange
bodies (insects, leaves, etc.), flooding hazards or any other exceptional events;
02 - Check if the main power supply voltage is the same one as requested in this manual;
03 - Check if there is suitable electrical protection against short circuits/power spikes and proper ground
on the main power supply.
04 - Take care with the control unit: parts may be subject to damage if abused;
05 - Make sure you have all the necessary materials and that they are suitable for this kind of use;
06 - Read all the instructions through at least once;
07 - Before starting the installation, carefully analyze all the risks regarding the automatization of the
Pág. 18