Technical Data - RODCRAFT RC600 Manual Del Operador

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
EN
English
(English)

TECHNICAL DATA

Model
Voltage
12 V
RC600
24 V
MACHINE TYPE ( S )
• This product is designed to help to start vehicle engine in case of emergency. No other use permitted. For professional use only.
• Please read the instructions carefully before starting the machine.
OPERATION
The Batteryless Start Booster relies on the instant recharging of supercapacitors rather than stored electric energy like batteries. There-
fore, it can be stored for years without regular recharges. It's totally maintenance free!
CAUTION: Before first use make sure to charge the Batteryless Start Booster with the supplied automatic
charger adaptor for at least 8 hours.
Checking the power level of the Batteryless Start Booster
• Switch the 12V OFF 24V switch to the 12V OR 24V position and Press the yellow test button for 2-5 seconds. The power level will be
displayed with digits.
• Make sure the unit is fully charged before using it (the 5 LEDs lights must be on).
• If the voltage level lit until the yellow led light, or the digital voltmeter shows below than 13.5V on 12V position and 26V for 24V position,
the Device should be recharged before use.
Charging the Batteryless Start Booster with the automatic charger adaptor
• Make sure the clamps are secure in their respective designated holders before charging.
• Make sure the charger adaptor and Batteryless Start Booster are placed in a well-ventilated, dry, non-flammable area during charge.
• Plug the supplied charger adaptor into the AC power outlet and then into the DC JACK socket on the Batteryless Start Booste . Switch
the 12V OFF 24V main switch to the "12V" position.
• The charger included with your device is fully automatic and may be left on and connected when the Batteryless Start Booster is fully
charged.
To keep the Batteryless Start Booster ready to use, recharge it at least every 90 days with the supplied automatic charger adaptor. However,
when not in use it is strongly recommended to always keep it connected to the supplied automatic charger adaptor to be used anytime.
Charging the Batteryless Start Booster through the clamps with a running vehicle
Note: Charging with a running vehicle requires much shorter time than charging with the automatic charger adaptor.
Caution: Charging with a running vehicle is not automatic and requires the operator to manually observe the
charging of the Batteryless Start Booster and the power level status. Always make sure the vehicle is running
and never leave the Batteryless Start Booster connected for long time and charging unattended.
Caution : Make sure to connect a 12V model to a 12V battery or vehicle, and 24V model to a 24V charging
method.
1. Make sure the vehicle ignition is in the "OFF" position.
2. Make sure the main switch of the Batteryless Start Booster is on the "OFF" position
3. Connect first the positive (red) clamp to the positive terminal of the battery
4. Then connect the negative (black) clamp to the negative terminal of the battery, or to the block of the engine or to the frame of the
vehicle (ground)
5. Make sure the device is stable and the cables are not in the path of moving belts, fans, etc...
6. Make sure the reverse polarity alarm is not making a loud noise and blinking.
7. Once the clamps are positioned correctly, start the vehicle
8. Turn the main switch to the "ON" position
The Batteryless Start Booster will charge automatically within a few seconds.
Caution : DO NOT leave it connected for more than 2 minutes.
To check the power level status, press the yellow test button for 2-5 seconds.
9. When the Batteryless Start Booster is charged, turn the main switch to "OFF" position.
10. Always disconnect the clamps one at a time starting with the negative (black) and then the positive (red).
11. Store both clamps in their respective designated holders.
starting
Amp. Max
Current
1600 A peak
4000 A
8 000 A peak
2000 A
Batteryless Start Booster
Capacitor life
30 sec. By running engine
1 000 000 cycles
6-7 Hours by AC adaptor
Ultra Capacitor
Full Charging Time
RC600
Weight
17 kg
Tabla de contenido