INSTALLATION INSTRUCTIONS
4) 3-WIRE POWER CORD INSTALLATION
WARNING
The neutral or ground wire of the power cord
must be connected to the neutral terminal
located in the center of the terminal block.
The power leads must be connected to the
lower left and the lower right terminals of the
terminal block.
(A) Remove the 3 lower terminal screws from
the terminal block. Insert the 3 terminal screws
through each power cord terminal ring and into
the lower terminals of the terminal block. Be
certain that the center wire (white/neutral) is
connected to the center lower position of the
terminal block. Tighten screws securely into the
terminal block. DO NOT remover the ground
strap connection.
(B) Skip to Step 8 and proceed with the
installation.
5) 4-WIRE POWER CORD INSTALLATION
WARNING
The neutral wire of the supply circuit must
be connected to the neutral terminal located
in the lower center of the terminal block.
The power leads must be connected to the
lower left and the lower right terminals of the
terminal block. The 4th grounding lead must
be connected to the frame of the range with
the ground plate and the ground screw.
(A) Remove the 3 lower terminal screws from the
terminal block. Remover the ground screw and
ground plate and retain them.
(B) Cut and discard the ground strap. DO NOT
DISCARD ANY SCREWS.
(C) Insert the one ground screw into the power
cord ground wire terminal ring, through the
ground plate and into the frame of the range.
(D) Insert the 3 terminal screws (removed earlier)
through each power cord terminal ring and into
the lower terminals of the terminal block. Be
certain that the center wire (white/neutral) is
connected to the center lower position of the
terminal block. Tighten the screws securely into
the terminal block.
(E) Skip to Step 8 and proceed with the
installation.
Ground
plate
Power cord
Before
Terminal
block
Cut and discard
the ground strap
After
Terminal
block
Ground
screw
21
Terminal block
(appearance may
vary)
Neutral
terminal
Ground
strap
Ground strap
or
Neutral
terminal
Neutral
terminal
Ground plate
(grounding
to range)