HOW TO USE THE HOB
Do not let the burner flame extend beyond the edge of the pan.
WARNING
IMPORTANT: WHEN THE HOB IS IN USE, THE ENTIRE HOB AREA MAY BECOME HOT.
• To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting.
• Press the knob against the control panel to ignite the burner.
• After the burner has ignited, keep the knob pressed for about 5-10 seconds to allow proper device operation.This burner safety device shuts off the gas supply to
the burner if the flame goes out accidentally (because of sudden draught, an interruption in the gas delivery, boiling over of liquids, etc.).
• The knob must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not remain lit,wait at least one minute before trying
to light it again. In the event of the burners flames being accidentally extinguished, turn off the burner control and do not attempt to reignite it for at least one minute.
NOTE: should particular local conditions of the delivered gas make the ignition of burner difficult, it is advisable to repeat the operation with the knob turned to small
flame setting.
The burner might go out when the knob is released. This means that the safety device has not warmed up enough. In this case, repeat the operations
described above.
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: if the distance "A" between the wall cabinets is
between 600 mm and 730 mm, the height "B" must be a
minimum of 530 mm.
if the distance "A" between the wall cabinets is greater
than the width of the hob, the height "B" must be a
minimum of 400 mm.
In case of installation of a hood above the hob, please refer
to the hood instructions fot the correct distance.
INJECTORS TABLE
Type of gas
Type of burner
used
Rapid
NATURAL GAS
Semi-rapid
(Methane) G20
Auxiliary
Rapid
LIQUEFIED
PETROLEUM GAS
Semi-rapid
G30
(Butane)
Auxiliary
Rapid
LIQUEFIED
PETROLEUM GAS
Semi-rapid
(Propane)
G31
Auxiliary
Type of gas used
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz 0.6W
Injector
marking
115Y
95Z
72X
85
63
50
85
63
50
Model con guration
4 BURNERS
1 R - 2 SR - 1 AUX
1 R - 2 SR - 1 AUX
1 R - 2 SR - 1 AUX
Rated thermal
Rated
ow rate
consumption
kW
3.00
286 l/h
1.75
167 l/h
1.00
95 l/h
3.00
218 g/h
1.75
127 g/h
1.00
73 g/h
3.00
214 g/h
1.75
125 g/h
1.00
71 g/h
Rated thermal
ow rate (kW)
consumption
7.50
7.50
7.50
Reduced heat
capacity
kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated
Air required (m
burning 1 m
715 l/h
545 g/h
535 g/h
CATEGORY II2H3+
Gas pressure
mbar
min.
rat.
max.
17
20
25
20
28-30
35
25
37
45
3
) for
3
of gas
9.52
30.94
23.80