Settings Adjustment - KS ALAMO Serie Manual De Instalación Y Funcionamiento

Grifo electrónico para lavabo
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

sETTINGs ADjUsTMENT

DETECTION
RANgE
DELAY IN TIME
SECuRITY TIME
COMFORT FLuSH
Adjusting the settings with the remote control
If necessary, the sensor settings can be adjusted as following:
Shut off the water supply. In order to adjust the sensor with the remote control,
hold the remote control straight in front of the sensor in a distance of about
6-8" (15-20cm). Choose the function you want to adjust by pressing once on
one of the function buttons. After pressing once on a specific function button, a
quick flashing of the LED at the front of the sensor will occur. At this stage, you
can change the setting by pressing the (+) or the (-) buttons, every push will
increase or decrease one level. After finishing the adjustment, turn the water
supply back on.
8
DELAY OuT TIME
TEMPORARY OFF
FuNCTION
SELF ADJuSTMENT
MODE
RESET
HYgIENE FLuSH
sETTINGs ADjUsTMENT
DETECTION RANgE:
adjusting sensor. The ideal detection range for the specific
location will be set automatically.
Only if necessary, use the remote control to adjust the sensor
range as follows:
Press the RANgE button. wait until a quick flashing of the LED
in the sensor eye is perceived. Then, press + to increase the
range and – to reduce it. Every push will increase or decrease
one level.
Note: Once you have changed the detection range with the remote control,
the distance will be remembered by the sensor, even if the power source is
disconnected. To get back to the self adjustment mode, use the ADJ button only.
ENTRANCE TO THE SELF ADJuSTMENT MODE: Check that no
objects are in front of the sensor. Press the ADJ button. Once a
quick flashing of the LED of the sensor eye is perceived, remove
your hand holding the remote control and move away from the
sensor area. The ideal sensor range for the specific location will
be set automatically. Once the self adjustment has taken place,
the solenoid valve will be opened and closed for 1 second as an
indication that the ideal sensor range was set and the product
is ready for use.
SECuRITY TIME: The Security time, prevents continuous
running of water due to reflections or vandalism. By default,
if the sensor is covered for more than 90 seconds the water
flow will shut automatically. To resume regular operation any
obstruction must be removed.
Press the SEC button. wait until a quick flashing of the LED in the
sensor eye is perceived. Then, press + to increase the security
time and – to reduce it.
This faucet was supplied with a self
9

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Ksl00495Ksl00496Ksl00480Ksl00490

Tabla de contenido